Effects of Electrical Stimulation Parameters on Fatigue in Skeletal Muscle
Authors:
- Ashraf S. GorgeyAshraf S. Gorgey
- Christopher D. BlackCBChristopher D. Black
- Christopher P. ElderCEChristopher P. Elder
- Gary A. DudleyGDGary A. Dudley
- 1 September 2009
- journal article
- research article
- Published by Journal of Orthopaedic & Sports Physical Therapy (JOSPT) in Journal of Orthopaedic & Sports Physical Therapy
- Vol. 39 (9) , 684-692
Abstract
Experimental laboratory study. The primary purpose was to investigate the independent effects of current amplitude, pulse duration, and current frequency on muscle fatigue during neuromuscular electrical stimulation (NMES). A second purpose was to determine if the ratio of the evoked torque to the activated area could explain muscle fatigue. Parameters of NMES have been shown to differently affect the evoked torque and the activated area. The efficacy of NMES is limited by the rapid onset of muscle fatigue. Seven healthy participants underwent 4 NMES protocols that were randomly applied to the knee extensor muscle group. The NMES protocols were as follows: standard protocol (Std), defined as 100-Hz, 450-micros pulses and amplitude set to evoke 75% of maximal voluntary isometric torque (MVIT); short pulse duration protocol (SP), defined as 100-Hz, 150-micros pulses and amplitude set to evoke 75% of MVIT; low-frequency protocol (LF), defined as 25-Hz, 450-micros pulses and amplitude set to evoke 75% of MVIT; and low-amplitude protocol (LA), defined as 100-Hz, 450-micros pulses and amplitude set to evoke 45% of MVIT. The peak torque was measured at the start and at the end of the 4 protocols, and percent fatigue was calculated. The outcomes of the 4 NMES protocols on the initial peak torque and activated cross-sectional area were recalculated from a companion study to measure torque per active area. Decreasing frequency from 100 to 25 Hz decreased fatigue from 76% to 39%. Decreasing the amplitude and pulse duration resulted in no change of muscle fatigue. Torque per active area accounted for 57% of the variability in percent fatigue between Std and LF protocols. Altering the amplitude of the current and pulse duration does not appear to influence the percent fatigue in NMES. Lowering the stimulation frequency results in less fatigue, by possibly reducing the evoked torque relative to the activated muscle area.Keywords
This publication has 39 references indexed in Scilit:
- The Role of Pulse Duration and Stimulation Duration in Maximizing the Normalized Torque During Neuromuscular Electrical StimulationJournal of Orthopaedic & Sports Physical Therapy, 2008
- Effects of stimulation frequency versus pulse duration modulation on muscle fatigueJournal of Electromyography and Kinesiology, 2008
- Neuromuscular Electrical Stimulation Versus Volitional Isometric Strength Training in Children With Spastic Diplegic Cerebral Palsy: A Preliminary StudyNeurorehabilitation and Neural Repair, 2007
- The effects of stimulation frequency and fatigue on the force–intensity relationship for human skeletal muscleClinical Neurophysiology, 2007
- Random Motor Unit Activation by ElectrostimulationInternational Journal of Sports Medicine, 2007
- Impact of varying pulse frequency and duration on muscle torque production and fatigueMuscle & Nerve, 2007
- Central and Peripheral Fatigue of the Knee Extensor Muscles Induced by ElectromyostimulationInternational Journal of Sports Medicine, 2005
- An age-related shift in the force-frequency relationship affects quadriceps fatigability in old adultsJournal of Applied Physiology, 2004
- Variable frequency trains enhance torque independent of stimulation amplitudeActa Physiologica Scandinavica, 2002
- The Effects of Electromyostimulation Training and Basketball Practice on Muscle Strength and Jumping AbilityInternational Journal of Sports Medicine, 2000