Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection
- 30 March 2010
- journal article
- research article
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 49 (3) , 337-343
Abstract
For real-time monitoring of the longitudinal position of the Bragg-peak during an ion therapy treatment, a novel non-invasive technique has been recently proposed that exploits the detection of prompt γ-rays issued from nuclear fragmentation. Two series of experiments have been performed at the GANIL and GSI facilities with 95 and 305 MeV/u 12C6+ ion beams stopped in PMMA and water phantoms. In both experiments, a clear correlation was obtained between the carbon ion range and the prompt photon profile. Additionally, an extensive study has been performed to investigate whether a prompt neutron component may be correlated with the carbon ion range. No such correlation was found. The present paper demonstrates that a collimated set-up can be used to detect single photons by means of time-of-flight measurements, at those high energies typical for ion therapy. Moreover, the applicability of the technique both at cyclotron and at synchrotron facilities is shown. It is concluded that the detected photon count rates provide sufficiently high statistics to allow real-time control of the longitudinal position of the Bragg-peak under clinical conditions.Keywords
This publication has 13 references indexed in Scilit:
- Dose profile monitoring with carbon ions by means of prompt-gamma measurementsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2009
- Monitoring the Bragg peak location of 73MeV∕u carbon ions by means of prompt γ-ray measurementsApplied Physics Letters, 2008
- Secondary beam fragments produced by 200 MeV u−112C ions in water and their dose contributions in carbon ion radiotherapyNew Journal of Physics, 2008
- PET imaging for treatment verification of ion therapy: Implementation and experience at GSI Darmstadt and MGH BostonNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Prompt gamma measurements for locating the dose falloff region in the proton therapyApplied Physics Letters, 2006
- Investigating the accuracy of the FLUKA code for transport of therapeutic ion beams in matterPhysics in Medicine & Biology, 2006
- Discrimination methods between neutron and gamma rays for boron loaded plastic scintillatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Tumor therapy with heavy charged particlesProgress in Particle and Nuclear Physics, 2000
- A full-integrated pulse-shape discriminator for liquid scintillator countersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998
- Exclusive photon yields from peripheral collisions of 40Ar+158Gd at 44 MeV/uNuclear Physics A, 1989