Dezincification of brass water meters in a long-term study: effects of anions, alkalinity, and residual chlorine
- 15 July 2021
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 7 (9) , 1666-1676
Abstract
The dezincification of brass water meters in a water distribution system is affected by tap water characteristics. However, the effects of mixed water quality on corrosion and scale formation on the behaviour of brass water meters have remained unclear. This study investigated the long-term impact of tap water characteristics on the brass dezincification of commercial water meters, using a household-simulated circulating pipeline system. The effect of water anions, alkalinity, and residual chlorine on dezincification and corrosion of such brass water meters were quantitatively and electrochemically examined for over a period of 376 days. The results show that water meters suffer the most severe dezincification when the tap water has a high level of anions (SO4 2−: 120 mg L−1 and Cl−: 60 mg L−1) and low alkalinity (120 mg L−1 as CaCO3). Under such conditions, a considerable amount of zinc is leached, amounting to 146–153 mg L−1 over 376 days, accompanied by high corrosion rates of 42.2–45.8 μm per year. Exposure to water with high anionic concentrations and low alkalinity also results in a positive shift of 15 to 50 mV in the corrosion potential of chips of scaled brass, leading to heavy scale formation. The majority of Zn (∼50%) in the scale was demonstrated by ICP-OES and SEM/EDS. The data obtained from XPS suggest that scales of ZnCO3/Zn(OH)2 formed as a result of the long-term dezincification of brass. By contrast, minor dezincification was observed when the water meters were exposed to water of low anionic concentrations (SO4 2−: 60 mg L−1 and Cl−: 6 mg L−1), low alkalinity (120 mg L−1 as CaCO3), and low residual chlorine (0.2 mg L−1 as Cl2), even after 376 days. Under these conditions, the accumulative amount of zinc leaching and the corrosion rate were only 105 mg L−1 and 13.2 μm per year, which are significantly lower than those obtained in the high anion concentration and low alkalinity situations. This study provides a further insight into how tap water characteristics impact the long-term brass dezincification of water meters, which benefits water utilities to forecast scale formation under specific tap water conditions.Keywords
This publication has 30 references indexed in Scilit:
- Surface study of films formed on copper and brass at open circuit potentialApplied Surface Science, 2013
- Atmospheric corrosion of brass in outdoor applicationsScience of The Total Environment, 2011
- Effects of flow, brass location, tube materials and temperature on corrosion of brass plumbing devicesCorrosion Science, 2011
- Stress corrosion cracking and selective corrosion of copper‐zinc alloys for the drinking water installationMaterials and Corrosion, 2009
- Electrochemical impedance study on brass corrosion in NaCl and (NH4)2SO4 solutions during cyclic wet?dry conditionsJournal of Applied Electrochemistry, 2005
- Dezincification of Brass and its Control - An OverviewCorrosion Reviews, 2003
- Copper corrosion by-product release in long-term stagnation experimentsWater Research, 2002
- Electron beam induced reduction of CuO in the presence of a surface carbonaceous layer: an XPS/HREELS studySurface Science, 1989
- Surface spectroscopic characterization of the interaction between zinc ions and $gamma;-aluminaJournal of Catalysis, 1984
- X-ray photoelectron studies on some oxides and hydroxides of cobalt, nickel, and copperAnalytical Chemistry, 1975