Nondestructive elemental depth profiling of Japanese lacquerware ‘Tamamushi‐nuri’ by confocal 3D‐XRF analysis in comparison with micro GE‐XRF
Authors:
- 8 April 2009
- journal article
- research article
- Published by Wiley in X-Ray Spectrometry
- Vol. 38 (5) , 446-450
Abstract
We have applied recently two XRF (micro x‐ray fluorescence) methods [micro‐Grazing Exit XRF (GE‐XRF) and confocal 3D‐XRF] to Japanese lacquerware ‘Tamamushi‐nuri.’ A laboratory grazing‐exit XRF (GE‐XRF) instrument was developed in combination with a micro‐XRF setup. A micro x‐ray beam was produced by a single capillary and a pinhole aperture. Elemental x‐ray images (2D images) obtained at different analyzing depths by micro GE‐XRF have been reported. However, it was difficult to directly obtain depth‐selective x‐ray spectra and 2D images. A 3D XRF instrument using two independent polycapillary x‐ray lenses and two x‐ray sources (Cr and Mo targets) was also applied to the same sample. 2D XRF images of a Japanese lacquerware showed specific distributions of elements at the different depths, indicating that ‘Tamamushi‐nuri’ lacquerware has a layered structure. The merits and disadvantages of both the micro GE‐XRF and confocal micro XRF methods are discussed. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
This publication has 18 references indexed in Scilit:
- Development of a compact XRF probe using a ring‐type secondary targetX-Ray Spectrometry, 2008
- Development of confocal micro X-ray fluorescence instrument using two X-ray beamsSpectrochimica Acta Part B: Atomic Spectroscopy, 2007
- Development of confocal 3D micro‐XRF spectrometer with dual Cr-Mo excitationX-Ray Spectrometry, 2007
- Development of Confocal 3D Micro XRF Spectrometer and Its Application to Rice GrainBUNSEKI KAGAKU, 2006
- Three-Dimensional Trace Element Analysis by Confocal X-ray Microfluorescence ImagingAnalytical Chemistry, 2004
- Confocal microscopic X-ray fluorescence at the HASYLAB microfocus beamline: characteristics and possibilitiesSpectrochimica Acta Part B: Atomic Spectroscopy, 2004
- Development and applications of grazing exit micro X-ray fluorescence instrument using a polycapillary X-ray lensSpectrochimica Acta Part B: Atomic Spectroscopy, 2004
- Feasibility study of three-dimensional XRF spectrometry using μ-X-ray beams under grazing-exit conditionsSpectrochimica Acta Part B: Atomic Spectroscopy, 2003
- Capillary optics and their use in x-ray analysisX-Ray Spectrometry, 2000
- Applications of x-ray and neutron capillary optics1993