Partial volume effect (PVE) on the arterial input function (AIF) in T1‐weighted perfusion imaging and limitations of the multiplicative rescaling approach
Open Access
- 11 August 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (4) , 1055-1059
Abstract
The partial volume effect (PVE) on the arterial input function (AIF) remains a major obstacle to absolute quantification of cerebral blood flow (CBF) using MRI. This study evaluates the validity and performance of a commonly used multiplicative rescaling of the AIF to correct for the PVE. In a group of six patients, perfusion imaging was performed using a T1‐weighted approach that minimizes confounding susceptibility artifacts. Various degrees of PVE were induced on the AIF and subsequently corrected using four different schemes of multiplicative AIF rescaling. Our results show that a multiplicative rescaling is not always applicable and can introduce a CBF bias. An easily measurable quantity denoted the tissue signal fraction (TSF) is proposed as a measure of the applicability of a multiplicative rescaling. For the present CBF quantification method, a TSF of <0.4 results in a CBF bias <15% after AIF rescaling. Magn Reson Med, 2009.Keywords
Funding Information
- Lundbeck Foundation
This publication has 21 references indexed in Scilit:
- Identifying systematic errors in quantitative dynamic‐susceptibility contrast perfusion imaging by high‐resolution multi‐echo parallel EPINMR in Biomedicine, 2006
- Measurement of arterial input functions for dynamic susceptibility contrast magnetic resonance imaging using echoplanar images: Comparison of physical simulations with in vivo resultsMagnetic Resonance in Medicine, 2006
- The impact of partial‐volume effects in dynamic susceptibility contrast magnetic resonance perfusion imagingJournal of Magnetic Resonance Imaging, 2005
- Measuring the arterial input function with gradient echo sequencesMagnetic Resonance in Medicine, 2003
- Quantification of Perfusion Using Bolus Tracking Magnetic Resonance Imaging in StrokeStroke, 2002
- Methodology of brain perfusion imagingJournal of Magnetic Resonance Imaging, 2001
- Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRIMagnetic Resonance in Medicine, 2001
- Analysis of input functions from different arterial branches with gamma variate functions and cluster analysis for quantitative blood volume measurementsMagnetic Resonance Imaging, 2000
- Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: a direct comparison with Xe-133 SPECTMagnetic Resonance Materials in Physics, Biology and Medicine, 2000
- Measurement of cerebral perfusion with dual‐echo multi‐slice quantitative dynamic susceptibility contrast MRIJournal of Magnetic Resonance Imaging, 1999