Total Endoscopic Beating-Heart Coronary Artery Bypass Grafting using a New 3D Imaging System
Authors:
Open Access
- 1 September 2006
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 1 (5) , 243-246
Abstract
Objective: Since 1999, the authors of this study have performed total endoscopic beating-heart coronary artery bypass. They have developed a new three-dimensional (3D) endoscopic imaging system and have used it successfully in three patients. Methods: From January 2004, a new 3D endoscopic imaging system was used. This device, composed of an optical high-resolution, 3D endoscope and two liquid crystal monitors, gives bright, natural, 3D imaging and enables quick, precise manipulation. After the 15-mm port for the 3D endoscope was inserted through fourth intercostal space (ICS) in the posterior axillary line, the left internal thoracic artery (LITA) was taken down endoscopically in semiskeletonized fashion, using two instrumental 5-mm ports (third and sixth anterior axillary ICS). The pericardium was then opened, and the left anterior descending artery was identified. Another 10-mm port for an endoscopic needle holder was inserted through fourth ICS in the midclavicular line. Three ports were placed in the fourth ICS in line for the anastomosis. An original suction stabilizer was inserted through the first instrumental port, and the left anterior descending artery was immobilized. A conventional end-to-side anastomosis was done with 8–0 Prolene running sutures. Results: The average LITA harvesting time was significantly shortened from 68 minutes with two-dimensional imaging to 36 minutes with new 3D imaging. The average anastomotic time was shortened from 34 minutes with two-dimensional imaging and 27 minutes with former 3D imaging to 17 minutes with new 3D imaging. There were no complications and no operative deaths. Conclusions: This new 3D endoscopic imaging system facilitates quick, precise anastomosis and is a useful device for endoscopic coronary bypass surgery.Keywords
This publication has 10 references indexed in Scilit:
- Robotic Assisted Multivessel Minimally Invasive Direct Coronary Artery Bypass With Port-Access Stabilization and Cardiac Positioning: Paving the Way for Outpatient Coronary Surgery?The Annals of Thoracic Surgery, 2005
- Results of a phase one study on robotically assisted myocardial revascularization on the beating heartThe Annals of Thoracic Surgery, 2004
- Instant myocardial blood flow monitor: its calibration and assessment of flow capacity of the intracoronary shunt tubeThe Annals of Thoracic Surgery, 2004
- Robotic totally endoscopic coronary artery bypass: program development and learning curve issuesThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Totally endoscopic coronary artery bypass grafting on cardiopulmonary bypass with robotically enhanced telemanipulation: Report of forty-five casesThe Journal of Thoracic and Cardiovascular Surgery, 2002
- Technique of closed chest coronary artery surgery on the beating heartEuropean Journal of Cardio-Thoracic Surgery, 2001
- Initial United States clinical trial of robotically assisted endoscopic coronary artery bypass graftingThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Total endoscopic computer enhanced coronary artery bypass graftingEuropean Journal of Cardio-Thoracic Surgery, 2000
- Beating-heart endoscopic coronary artery surgeryThe Lancet, 1999
- Computer-enhanced coronary artery bypass surgeryThe Journal of Thoracic and Cardiovascular Surgery, 1999