Risk evaluation of decomposition of hydroxylamine/water solution at various concentrations
Authors:
- 1 June 2002
- journal article
- research article
- Published by Wiley in Process Safety Progress
- Vol. 21 (2) , 136-141
Abstract
The thermal property of HA/water solution was studied from the calorimetric data obtained using differential thermal analysis (DTA). The intensity of decomposition was studied from results of a mini closed pressure vessel test (MCPVT), and a pressure vessel test (PVT), in addition to the steel tube test.The thermal analysis was conducted to evaluate the ease of thermal decomposition using DTA. The heat‐release onset temperatures using the no‐treated stainless steel cells were more than 70° C below those measured using the gold‐coated stainless steel cells. This result implies that the heat‐release onset temperature depends on the materials of the sample cell.The intensity of the thermal decomposition was investigated using the MCPVT, the PVT, and the steel tube test. The intensity of the thermal decomposition increased as the HA concentration increased in the MCPVT. The intensity of the thermal decomposition increased greatly when the HA concentration was beyond 80% (wt.) in the MCPVT. It was determined that the thermal decomposit ion of HA 70%/water solutions was very violent in the PVT. In addition, HA/water solutions of more than 80% concentration could detonate in the steel tube test.Keywords
This publication has 1 reference indexed in Scilit:
- Adiabatic calorimetric decomposition studies of 50 wt.% hydroxylamine/waterJournal of Hazardous Materials, 2001