A membrane introduction mass spectrometer utilizing ion‐molecule reactions for the on‐line speciation and quantitation of volatile organic molecules
- 27 October 2015
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 29 (23) , 2187-2194
Abstract
Rationale: The ability of membrane introduction mass spectrometry to quantitatively resolve low molecular weight volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene and xylene (BTEX) using electron ionization (EI) can be compromised by isobaric interferences. This work focuses on reducing isobaric interferences with ion‐molecule reactions in a portable quadrupole ion trap mass spectrometer for the analysis of VOCs. Methods: EI was used to produce reagent ions from precursors (chloroform, methyl iodide, trichloroethylene or chlorobenzene) that were continually infused into the helium acceptor phase upstream of the membrane introduction mass spectrometry (MIMS) sampling interface. The reagent ions were selectively stored in the ion trap, and then allowed to react with target VOC analytes in air samples via ion‐molecule reactions within the trap storage volume. A variety of reaction times were examined (50–5000 ms), and the resulting product ions were analyzed in positive ion mode. Results: The detection limits achieved were comparable with those obtained using EI (low ppb v ), and in some cases better than for EI coupled with tandem mass spectrometry (MS/MS). For the VOCs studied, isobaric interferences were greatly reduced or eliminated using chloroform as a reagent gas. The predominant ionization mechanism was via adduct formation, although charge transfer and hydride abstractions were also observed. An internal standard was shown to be effective at correcting for signal changes due to consumption of reagent ions when complex mixtures were sampled. Conclusions: Ion‐molecule reactions were exploited to eliminate isobaric interferences that are often encountered in direct, real‐time analysis strategies for atmospheric VOC mixtures. The use of a continuously infused internal standard will improve quantitative results in field applications where analyte concentration and sample complexity may be wide ranging. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
This publication has 40 references indexed in Scilit:
- Membrane-introduction mass spectrometry (MIMS)TrAC Trends in Analytical Chemistry, 2011
- Release of VOCs and Particles During Use of Nanofilm Spray ProductsEnvironmental Science & Technology, 2009
- Fast and direct screening of polyaromatic hydrocarbon (PAH)‐contaminated sand using a miniaturized membrane inlet mass spectrometer (mini‐MIMS)Rapid Communications in Mass Spectrometry, 2007
- A Fast-Response Method for Determination of Atmospheric Isoprene Using Quadrupole Ion Trap Mass SpectrometryAnalytical Chemistry, 1998
- Analysis of Volatile Organic Sulfur Compounds in Air by Membrane Inlet Mass SpectrometryAnalytical Chemistry, 1997
- Analysis of Polar Organic Compounds Using Charge Exchange Ionization and Membrane Introduction Mass SpectrometryAnalytical Chemistry, 1996
- Microporous membrane introduction mass spectrometry with solvent chemical ionization and glow discharge for the direct detection of volatile organic compounds in aqueous solutionAnalytica Chimica Acta, 1992
- Penning ionization electron spectroscopy of monohalobenzenes: fluorobenzene, chlorobenzene, bromobenzene, and iodohenzeneJournal of the American Chemical Society, 1986
- Recent improvements in and analytical applications of advanced ion trap technologyInternational Journal of Mass Spectrometry and Ion Processes, 1984
- Chemical Ionization Mass Spectrometry. I. General IntroductionJournal of the American Chemical Society, 1966