Abstract
BACKGROUND AND PURPOSE: Manual segmentation of infarct volume on follow‐up MRI diffusion‐weighted imaging (MRI‐DWI) is considered the gold standard but is prone to rater variability. We assess the variability of manual segmentations of MRI‐DWI infarct volume.METHODS: Consecutive patients (May 2018 to May 2019) with the anterior circulation stroke and endovascularly treated were enrolled. All patients underwent 24‐ to 32‐hour follow‐up MRI. Three users manually segmented DWI infarct volumes slice by slice twice. The reference standard of DWI infarct volume was generated by the STAPLE algorithm. Intra‐ and interrater reliability was evaluated using the intraclass correlation coefficient (ICC) by comparing manual segmentations with the reference standard. Spatial measurements were evaluated using metrics of the Dice similarity coefficient (DSC). Volumetric measurements were compared using the lesion volume.RESULTS: The dataset consisted of 44 patients, mean (SD) age was 70.1 years (±10.3), 43% were women, and median baseline NIHSS score was 16. Among three users, the mean DSC for MRI‐DWI infarct volume segmentations ranged from 80.6% ± 11.7% to 88.6% ± 7.5%, and the mean absolute volume difference was 2.8 ± 6.8 to 13.0 ± 14.0 ml. Interrater ICC among the users for DSC and infarct volume was .86 (95% confidence interval [95% CI]: .78‐.91) and .997 (95% CI: .995‐.998). Intrarater ICC for the three users was .83 (95% CI: .69‐.93), .84 (95% CI: .72‐.91), and .80 (95% CI: .64‐.89) for DSC, and .99 (95% CI: .987‐.996), .991 (95% CI: .983‐.995), and .996 (95% CI: .993‐.998) for infarct volume.CONCLUSIONS: Manual segmentation of infarct volume on follow‐up MRI‐DWI shows excellent agreement and good spatial overlap with the reference standard, suggesting its usefulness for measuring infarct volume on 24‐ to 32‐hour MRI‐DWI.Keywords
Funding Information
- Ministerstvo Školství, Mládeže a Tělovýchovy (LQ1605)
- Ministerstvo Zdravotnictví Ceské Republiky (FNOs/2018)
This publication has 39 references indexed in Scilit:
- Early Diffusion-Weighted Imaging and Perfusion-Weighted Imaging Lesion Volumes Forecast Final Infarct Size in DEFUSE 2Stroke, 2013
- Final Infarct Volume Is a Stronger Predictor of Outcome Than Recanalization in Patients With Proximal Middle Cerebral Artery Occlusion Treated With Endovascular TherapyStroke, 2012
- Infarct Volume Is a Pivotal Biomarker After Intra-Arterial Stroke TherapyStroke, 2012
- Effect of Time to Reperfusion on Clinical Outcome of Anterior Circulation Strokes Treated With ThrombectomyStroke, 2011
- Real‐time diffusion‐perfusion mismatch analysis in acute strokeJournal of Magnetic Resonance Imaging, 2010
- Ischemic lesion volume determination on diffusion weighted images vs. apparent diffusion coefficient mapsBrain Research, 2009
- Interexaminer Difference in Infarct Volume Measurements on MRIStroke, 2008
- The Impact of Recanalization on Ischemic Stroke OutcomeStroke, 2007
- Intra- and Interrater Reliability of Ischemic Lesion Volume Measurements on Diffusion-Weighted, Mean Transit Time and Fluid-Attenuated Inversion Recovery MRIStroke, 2006
- Simultaneous Truth and Performance Level Estimation (STAPLE): An Algorithm for the Validation of Image SegmentationIEEE Transactions on Medical Imaging, 2004