Generating multisinusoidal test signals by using a VSI for the identification of synchronous machines
Authors:
- 1 September 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
Despite the effectiveness of the standstill frequency-response test or SSFR test in identifying accurate electrical machine models, it has the disadvantage of being a time consuming method. Therefore the use of a broadband signal is proposed instead of the excitation of only one frequency in the test signal and this sequentially for different signal frequencies. Furthermore, the test signals are often generated by using a waveform generator externally applied to the machine, which is not commonly available in the field. In this paper the generation of broadband test signals by using a voltage-source inverter (VSI) resulting in a multisine SSFR test is discussed. Using this multisine SSFR test the influence of saturation and cross-saturation on the q- and d-axis parameters can be swiftly evaluated.Keywords
This publication has 4 references indexed in Scilit:
- Identification of PM synchronous machines in the frequency domain by broadband excitation2008
- A comparative analysis of pulsating vs. rotating vector carrier signal injection-based sensorless controlAPEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition, 2008
- Vector-optimised harmonic elimination for single-phase pulse-width modulation inverters/convertersIET Electric Power Applications, 2007
- A nonlinear model for synchronous machines to describe high-frequency signal based position estimators2005