No red cell alloimmunization or change of clinical outcome after using fresh frozen cancellous allograft bone for acetabular reconstruction in revision hip arthroplasty: a follow up study
Open Access
- 25 September 2012
- journal article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 187
Abstract
Background: Possible immunization to blood group or other antigens and subsequent inhibition of remodeling or incorporation after use of untreated human bone allograft was described previously. This study presents the immunological, clinical and radiological results of 30 patients with acetabular revisions using fresh frozen non-irradiated bone allograft. Methods: AB0-incompatible (donor-recipient) bone transplantation was performed in 22 cases, Rh(D) incompatible transplantation in 6 cases. The mean follow up of 23 months included measuring Harris hip score and radiological examination with evaluation of remodeling of the bone graft, implant migration and heterotopic ossification. In addition, all patients were screened for alloimmunization to Rh blood group antigens. Results: Compared to the whole study group, there were no differences in clinical or radiological measurements for the groups with AB0- or Rh(D)-incompatible bone transplantation. The mean Harris Hip Score was 80.6. X-rays confirmed total remodeling of all allografts with no acetabular loosening. At follow up, blood tests revealed no alloimmunization to Rh blood group donor antigens. Conclusions: The use of fresh frozen non-irradiated bone allograft in acetabular revision is a reliable supplement to reconstruction. The risk of alloimmunization to donor-blood group antigens after AB0- or Rh-incompatible allograft transplantation with a negative long-term influence on bone-remodeling or the clinical outcome is negligible.Keywords
This publication has 28 references indexed in Scilit:
- Impregnation of bone chips with alendronate and cefazolin, combined with demineralized bone matrix: a bone chamber study in goatsBMC Musculoskeletal Disorders, 2012
- Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight yearsBMC Musculoskeletal Disorders, 2010
- Impregnation of bone chips with antibiotics and storage of antibiotics at different temperatures: an in vitro studyBMC Musculoskeletal Disorders, 2010
- Acetabular bone reconstruction in revision arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2008
- Acetabular revision with freeze-dried irradiated and chemically treated allograft: a minimum 5-year follow-up of 17 casesInternational Orthopaedics, 2007
- Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graftThe Journal of Bone and Joint Surgery. British volume, 2007
- Acetabular revision with the Burch-Schnieder antiprotrusio cage and cancellous allograft boneThe Journal of Arthroplasty, 1995
- Acetabular defect classification and surgical reconstruction in revision arthroplastyThe Journal of Arthroplasty, 1994
- No irregular erythrocyte antibodies observed after bone allografts in 144 patientsActa Orthopaedica, 1993
- Rhesus immunization after bone allografting: A case reportActa Orthopaedica, 1987