Bacterial Contamination of Mobile Phones Used by Healthcare Workers in Critical Care Units: A Cross-Sectional Study from Saudi Arabia
Authors:
- Nabil DhayhiNDNabil Dhayhi
- Nader KameliNKNader Kameli
- Mohammed SalawiMSMohammed Salawi
- Amjad ShajriASAmjad Shajri
- Vinod Kumar BasodeVBVinod Kumar Basode
- Abdullah AlgaissiAAAbdullah Algaissi
- Edrous AlamerEAEdrous Alamer
- Majid DarrajMDMajid Darraj
- Khalid ShrwaniKSKhalid Shrwani
- Abdulaziz H. AlhazmiAAAbdulaziz H. Alhazmi
Open Access
- 2 August 2023
- journal article
- research article
- Published by MDPI AG in Microorganisms
- Vol. 11 (8) , 1986
Abstract
Background: Healthcare-associated infections (HAIs) present a formidable challenge for healthcare institutions, resulting in heightened mortality, morbidity, and economic burden. Within healthcare settings, various equipment and materials, including mobile phones, can potentially act as sources of infection. This study sought to examine the occurrence of bacterial contamination on mobile phones utilized by healthcare workers (HCWs) in intensive care units (ICUs), pediatric intensive care units (PICUs), neonatal intensive care units (NICUs), and cardiac care units (CCUs) within a central hospital (CH) and two peripheral hospitals (PHs) situated in the southwestern province of Saudi Arabia. Materials and methods: We collected a total of 157 samples from mobile phones utilized by HCWs across all ICUs in the CH and PHs. These samples underwent bacteriological analysis to evaluate the degree of bacterial contamination. Results: We found that 45 out of 55 samples from physicians (81.81%) and 58 out of 77 samples from nurses (75.32%) showed bacterial contamination. Contamination rates on HCWs’ mobile phones in the ICU, PICU, and NICU departments of the CH were observed at 69.56%, 80.95%, and 70.27%, respectively. Furthermore, the overall contamination rates in the ICUs, NICUs, and CCUs of the PHs were 78.26%, 88.88%, and 66.66%, respectively. The overall contamination rates of mobile phones in the CH and PHs were 72.11% and 81.13%, respectively. Conclusion: These findings underscore the necessity of routinely disinfecting the mobile phones of HCWs to mitigate the risk of cross-contamination. Implementing robust disinfection protocols can significantly contribute to curtailing the propagation of bacterial pathogens and reducing the incidence of HAIs in healthcare settings.Keywords
Funding Information
- Deanship of Scientific Research, Jazan University, Research Units Support Program (RUP2-05)
This publication has 33 references indexed in Scilit:
- Microbiological contamination of mobile phones of clinicians in intensive care units and neonatal care units in public hospitals in KuwaitBMC Infectious Diseases, 2015
- A mobil kommunikációs eszközök szerepe a fertőzések átvitelében. Szisztematikus irodalomelemzésOrvosi Hetilap, 2015
- Mobile phones: Reservoirs for the transmission of nosocomial pathogensAdvanced Biomedical Research, 2015
- Mobile phones in clinical practice: reducing the risk of bacterial contaminationInternational Journal Of Clinical Practice, 2014
- Mobile phone technology and hospitalized patients: a cross-sectional surveillance study of bacterial colonization, and patient opinions and behavioursClinical Microbiology and Infection, 2011
- Prevalence and Type of Microorganisms Isolated from House Staffs Mobile Phones before and after Alcohol CleaningInfection Control & Hospital Epidemiology, 2011
- Bacterial flora on cell phones of health care providers in a teaching institutionAmerican Journal of Infection Control, 2010
- Isolation and identification of microbes associated with mobile phones in Dammam in eastern Saudi ArabiaJournal of Family and Community Medicine, 2010
- Use of mobile phones by medical staff at Queen Elizabeth Hospital, Barbados: evidence for both benefit and harmJournal of Hospital Infection, 2008
- Antimicrobial Stewardship Programs in Health Care SystemsClinical Microbiology Reviews, 2005