Pipeline Leak Detection by Impulse Response Extraction
Author:
- 1 December 1998
- journal article
- Published by ASME International in Journal of Fluids Engineering
- Vol. 120 (4) , 833-838
Abstract
A system’s response to an impulse can be used to detect and diagnose abnormalities. The impulse response can be extracted by using cross-correlations between a low amplitude pseudo random binary disturbance input and the system’s output. This fact is applied to pipeline hydraulics as a means of real-time non-interruptive integrity monitoring. A method of generating the pseudo random binary disturbance is proposed. The extraction of a pipeline’s impulse response with the presence of noise is investigated. The features of the response of an intact pipeline and characteristic changes in the impulse response as a result of a leak are established. The feasibility of using impulse response to detect and to locate a leak in real-time is demonstrated.Keywords
This publication has 4 references indexed in Scilit:
- Pipeline Integrity Monitoring Using System Impulse Response1996
- Leak Detection—Transient Flow Simulation ApproachesJournal of Energy Resources Technology, 1995
- Time Series1990
- A Crosscorrelation Method for Measuring the Impulse Response of Reactor SystemsNuclear Science and Engineering, 1961