Comparison of single radial immunodiffusion and ELISA for the quantification of immunoglobulin G in bovine colostrum, milk and calf sera
Open Access
- 2 November 2017
- journal article
- research article
- Published by Taylor & Francis in Journal of Applied Animal Research
- Vol. 46 (1) , 758-765
Abstract
The overall objective was to compare immunoglobulin G (IgG) concentrations measured by single radial immunodiffusion (sRID) and ELISA-based methods in samples of bovine colostrum and transition milk from contrasting breed types (Limousin × Friesian (n = 10) and Holstein (n = 10)). Jugular blood samples were collected at 48 h post-birth from beef (n = 10) and dairy (n = 10) calves and sera harvested subsequent to colostrum consumption. Absolute colostrum IgG values determined by ELISA showed poor agreement with mean (SD) IgG values measured using sRID, fixed bias (sRID – ELISA) was 31.89 (±9.84) mg/mL; having wide limits of agreement (12.61–51.17) and a low concordance coefficient (0.26). The agreement between ELISA and sRID when measuring serum IgG was greater than that of colostrum, fixed bias (sRID – ELISA) was 12.36 (±6.60) mg/mL; having narrower limits of agreement (−0.58 to 25.30) and serum IgG concentrations had a greater concordance coefficient (0.44) between samples. Calf sera IgG measured using the indirect zinc sulphate turbidity test showed a strong correlation with the sRID and ELISA methods (P < .001), R2 = 0.78 and R2 = 0.77 respectively. Overall, the ELISA and sRID methodologies had a strong positive association with almost a twofold (1.8) difference between values; therefore, they provide diverse absolute values of IgG concentration.Keywords
Funding Information
- Agrisearch
- Department of Agriculture, Food and Marine, Ireland (11/S/131)
- Department of Agriculture and Rural Development in Northern Ireland
This publication has 38 references indexed in Scilit:
- Evaluation of on-farm tools for colostrum quality measurementJournal of Dairy Science, 2015
- Colostrogenesis: IgG1 Transcytosis MechanismsJournal of Mammary Gland Biology and Neoplasia, 2014
- Factors associated with the concentration of immunoglobulin G in the colostrum of dairy cowsAnimal, 2013
- An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattleJournal of Dairy Science, 2010
- Prevalence of failure of passive transfer of immunity in newborn heifer calves and associated management practices on US dairy operationsJournal of Dairy Science, 2009
- Comparison of Two Commercial Radial Immunodiffusion Assays for Detection of Bovine Immunoglobulin G in Newborn CalvesJournal of Veterinary Diagnostic Investigation, 2008
- Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foalsJournal of the American Veterinary Medical Association, 2005
- Evaluation of a commercially available immunoassay for assessing adequacy of passive transfer in calvesJournal of the American Veterinary Medical Association, 2002
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Early Variations of Blood Plasma Gamma-Glutamyl Transferase in Newborn Calves — A Test of Colostrum IntakeJournal of Dairy Science, 1982