Outcomes of Sutureless Iris-Claw Lens Implantation
Open Access
- 24 August 2016
- journal article
- research article
- Published by Wiley in Journal of Ophthalmology
- Vol. 2016, 1-7
Abstract
Purpose. To evaluate the indications, refraction, and visual and safety outcomes of iris-claw intraocular lens implanted retropupillary with sutureless technique during primary or secondary operation.Methods. Retrospective study of case series. The Haigis formula was used to calculate intraocular lens power. In all cases the wound was closed without suturing.Results. The study comprised 47 eyes. The mean follow-up time was 15.9 months (SD 12.2). The mean preoperative CDVA was 0.25 (SD 0.21). The final mean CDVA was 0.46 (SD 0.27). No hypotony or need for wound suturing was observed postoperatively. Mean postoperative refractive error was −0.27 Dsph (−3.87 Dsph to +2.85 Dsph; median 0.0, SD 1.28). The mean postoperative astigmatism was −1.82 Dcyl (min −0.25, max −5.5; median −1.25, SD 1.07). Postoperative complications were observed in 10 eyes. The most common complication was ovalization of the iris, which was observed in 8 eyes. The mean operation time was 35.9 min (min 11 min, max 79 min; median 34, SD 15.4).Conclusion. Retropupilary iris-claw intraocular lens (IOL) implantation with sutureless wound closing is an easy and fast method, ensuring good refractive outcome and a low risk of complication. The Haigis formula proved to be predictable in postoperative refraction.Keywords
This publication has 20 references indexed in Scilit:
- Secondary iris-claw anterior chamber lens implantation in patients with aphakia without capsular supportBritish Journal of Ophthalmology, 2014
- Aphakia correction with retropupillary fixated iris-claw lens (Artisan) – long-term resultsClinical Ophthalmology, 2013
- Visual outcome and complications after posterior iris-claw aphakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2012
- Three-year follow-up of secondary anterior iris fixation of an aphakic intraocular lens to correct aphakiaJournal of Cataract & Refractive Surgery, 2012
- Iris-claw intraocular lenses to correct aphakia in the absence of capsule supportJournal of Cataract & Refractive Surgery, 2011
- Intraocular architecture of secondary implanted anterior chamber iris-claw lenses in aphakic eyes evaluated with anterior segment optical coherence tomographyBritish Journal of Ophthalmology, 2009
- Webbasierte elektronische Krankenakte im Rahmen eines integrierten Versorgungskonzepts als Instrument der QualitätssicherungKlinische Monatsblätter für Augenheilkunde, 2009
- Five-Year Follow-up of 399 Phakic Artisan–Verisyse Implantation for Myopia, Hyperopia, and/or AstigmatismOphthalmology, 2008
- Pupil Ovalization After Phakic Intraocular Lens Implantation Is Associated With Sectorial Iris HypoperfusionArchives of Ophthalmology (1950), 2005
- Iris Claw LensAmerican Intra-Ocular Implant Society Journal, 1980