Abstract
Background: The lack of visualization of the spinal cord hinders the evaluation of [18F]Fluoro-deoxy-glucose (FDG) uptake of the spinal cord in PET/CT. By exploiting the capability of MRI to precisely outline the spinal cord, we performed a retrospective study aimed to define normal pattern of spinal cord [18F]FDG uptake in PET/MRI. Methods: Forty-one patients with lymphoma without clinical or MRI signs of spinal cord or bone marrow involvement underwent simultaneous PET and MRI acquisition using Siemens Biograph mMR after injection of 3.5 MBq/kg body weight of [18F]FDG for staging purposes. Using a custom-made software, we placed ROIs of 3 and 9 mm in diameter in the spinal cord, lumbar CSF, and vertebral marrow that were identified on MRI at 5 levels (C2, C5, T6, T12, and L3). The SUVmax, SUVmean, and the SUVmax and SUVmean normalized (NSUVmax and NSUVmean) to the liver were measured. For comparison, the same ROIs were placed in PET-CT images obtained immediately before the PET-MRI acquisition following the same tracer injection. Results: On PET/MRI using the 3 mm ROI, the following average (all level excluding L3) spinal cord median (1st and 3rd quartile) values were measured: SUVmean, 1.68 (1.39 and 1.83); SUVmax, 1.92 (1.60 and 2.14); NSUVmean, 1.18 (0.93 and 1.36); and NSUVmax, 1.27 (1.01 and 1.33). Using the 9 mm ROI, the corresponding values were SUVmean, 1.41 (1.25–1.55); SUVmax, 2.41 (2.08 and 2.61); NSUVmean, 0.93 (0.79 and 1.04); and NSUVmax, 1.28 (1.02 and 1.39). Using the 3 mm ROI, the highest values of PET-MRI SUVmax, SUVmean, NSUVmax, and NSUVmean were consistently observed at C5 and the lowest at T6. Using a 9 mm ROI, the highest values were consistently observed at C5 and the lowest at T12 or T6. The spinal cord [18F]FDG-uptake values correlated with the bone marrow uptake at the same level, especially in case of NSUVmax. Comparison with PET-CT data revealed that the average SUVmax and SUVmean of the spinal cord were similar in PET-MRI and PET-CT. However, the average NSUVmax and NSUVmean of the spinal cord were higher (range 21–47%) in PET-MRI than in PET-CT. Conclusions: Using a whole-body protocol, we defined the maximum and mean [18F]FDG uptake of the normal spinal cord in PET/MRI. While the observed values show the expected longitudinal distribution, they appear to be higher than those measured in PET/CT. Normalization of the SUVmax and SUVmean of the spinal cord to the liver radiotracer uptake could help in multi-institutional comparisons and studies.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- [18F]-Fluorodeoxyglucose–Positron Emission Tomography in Patients With Active MyelopathyMayo Clinic Proceedings, 2013
- Tumor Quantification in Clinical Positron Emission TomographyTheranostics, 2013
- Changes in18F-Fluorodeoxyglucose Uptake in the Spinal Cord in a Healthy Population on Serial Positron Emission Tomography/Computed TomographyChonnam Medical Journal, 2013
- Visualization of Distal Spinal Cord on F-18 FDG PET/CTClinical Nuclear Medicine, 2012
- Physiological 18F-FDG uptake by the spinal cord: is it a point of consideration for cancer patients?Journal of Neuro-Oncology, 2012
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Pattern of 18F-FDG Uptake in the Spinal Cord in Patients With Non-Central Nervous System MalignancySpine, 2011
- Is Liver SUV Stable over Time in 18F-FDG PET Imaging?Journal of Nuclear Medicine Technology, 2011
- A study of the accessory hepatic vein to segments VI and VII with a morphological reconsideration of the human liverSurgical and Radiologic Anatomy, 2008
- Morphologic Features of the Normal Human Cadaveric Spinal CordSpine, 1996