A new hand rehabilitation system based on the cable-driven mechanism and dielectric elastomer actuator
Authors:
Open Access
- 20 October 2020
- journal article
- research article
- Published by Copernicus GmbH in Mechanical Sciences
- Vol. 11 (2) , 357-369
Abstract
The increasing number of patients with hand disabilities after strokes or peripheral nerve injuries necessitates the continuous development of rehabilitation system devices to accelerate muscle recovery and to help patients regain the motor functions of their hands. This paper introduces the design of a hand rehabilitation system for patients who have a solitary impairment of their hand extension. The system was designed to be portable, simple, and cheap. Using a system based on a cable-driven mechanism instead of traditional rigid links reduces the degrees of freedom of the finger to one. The dielectric elastomer actuator was designed and fabricated as a smart actuator for the system, which supports the low cost of the system. A kinematic analysis of the cable-driven mechanism has been done. Parameters of the actuator were optimized to reach the required output. In order to characterize the performance of the actuator, a uniaxial tension test, isotonic test, and isometric test have been implemented.Keywords
This publication has 29 references indexed in Scilit:
- Analysis of the Forces on the Finger Joints by a Joint-Less Wearable Robotic Hand, SNU Exo-Glove2013
- Muscle-tendon units provide limited contributions to the passive stiffness of the index finger metacarpophalangeal jointJournal of Biomechanics, 2012
- Stroke rehabilitation: recent advances and future therapiesQJM: An International Journal of Medicine, 2012
- Design and Development of a Hand Exoskeleton for Rehabilitation Following StrokeProcedia Engineering, 2012
- Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation RobotJournal of NeuroEngineering and Rehabilitation, 2010
- HandCARE: A Cable-Actuated Rehabilitation System to Train Hand Function After StrokeIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2008
- The static actuation of dielectric elastomer actuators: how does pre-stretch improve actuation?Journal of Physics D: Applied Physics, 2008
- An arm wrestling robot driven by dielectric elastomer actuatorsSmart Materials and Structures, 2007
- Stereotypical Fingertip Trajectories During GraspJournal of Neurophysiology, 2003
- Computer animation of knowledge-based human graspingACM SIGGRAPH Computer Graphics, 1991