A protocol of urokinase infusion and warfarin for the management of the thrombosed haemodialysis catheter
Authors:
- Alan WebbAWAlan Webb
- Mubarak AbdallaMAMubarak Abdalla
- Gavin I. RussellGRGavin I. Russell
- 1 October 2001
- journal article
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 16 (10) , 2075-2078
Abstract
Catheter dysfunction remains a significant cause of catheter loss and interrupted haemodialysis sessions. A number of regimens utilizing urokinase have been used but the optimum management of this common problem remains undetermined. The study took place over 2 years and evaluated a protocol of urokinase infusion (25,000 U in 48 ml saline run at 4 ml/h via each limb of the catheter) followed by warfarin for restoration of catheter patency. Forty-eight urokinase infusions were used for 41 episodes of catheter dysfunction. Catheter patency was restored in 95% and only one catheter was lost. Recurrent thrombosis occurred in eight of 10 catheters not anticoagulated. Once anticoagulated, catheters worked well. Further episodes of non-function were related to a sub-therapeutic INR. Our results show a high success rate for our protocol. We suggest an aggressive approach to the management of catheter thrombosis with urokinase used by infusion and carefully controlled anticoagulation to maintain the INR in the range 2-2.5.Keywords
This publication has 14 references indexed in Scilit:
- Recombinant tissue plasminogen activator is a useful alternative to heparin in priming Quinton PermcathAmerican Journal of Kidney Diseases, 2000
- Transvenous Removal of Fibrin Sheaths from Tunneled Hemodialysis CathetersJournal of Vascular and Interventional Radiology, 1996
- Percutaneous Blood Access for HemodialysisSeminars in Dialysis, 1995
- Double Catheterization of the Internal Jugular Vein for Hemodialysis: Indications, Techniques, and Clinical ResultsArtificial Organs, 1994
- Salvage of Clotted Jugular Vein Hemodialysis CathetersNephron, 1994
- Thrombosed Central Venous Catheters: Restoring Function With 6‐Hour Urokinase Infusion After Failure of Bolus UrokinaseJournal of Parenteral and Enteral Nutrition, 1992
- Very Low Doses of Warfarin Can Prevent Thrombosis in Central Venous CathetersAnnals of Internal Medicine, 1990
- Successful use of double-lumen, silicone rubber catheters for permanent hemodialysis accessKidney International, 1989
- Fibrin Sleeve Formation on Indwelling Subclavian Central Venous CathetersArchives of Surgery, 1971
- Experience with Plastic Tubing in Prolonged Intravenous TherapyNew England Journal of Medicine, 1951