Abstract
A mathematical model based on energy and exergy methods is established to analyze the performance of an auto-cascade refrigeration system at varying compositions of the mixed refrigerants, condensation temperature, evaporation temperature, and vapor quality at the condenser outlet. Furthermore, grey correlation theory is employed to assess the correlation degrees between refrigerant mass fractions and system performance, enabling the identification of the state that has the greatest impact on the output parameters. It has been concluded that while maintaining a constant mass fraction of R600a, an increase in the mass fraction of R1150 (state 1) leads to a higher cooling capacity but a decrease in exergy efficiency. The performance decreases with the increase of the R600a mass fraction (state 2) as the R1150 mass fraction is unchanged. When the component of R14 is constant while the other two components R600a/R1150 vary (state 3), and the COP exists as the optimal value. The mixture of R600a/R1150/R14 with a mass fraction of 0.5:0.2:0.3 has better performance at COP of 0.5027 and exergy efficiency of 29.43 % under a condensation temperature of 30?. Based on the results of the grey correlation degree, the greatest factor in cooling capacity is state 1, while the COP and exergy efficiency are primarily controlled by state 3.Keywords
This publication has 16 references indexed in Scilit:
- Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration systemApplied Thermal Engineering, 2023
- Thermodynamic analysis of a novel ejector-enhanced auto-cascade refrigeration cycleApplied Thermal Engineering, 2022
- Thermodynamic analysis of auto-cascade refrigeration cycles, with and without ejector, for ultra low temperature freezing using a mixture of refrigerants R600a and R1150Applied Thermal Engineering, 2022
- Thermodynamic performance of a modified −150 °C refrigeration system coupled with Linde-Hampson and three-stage auto-cascade using low-GWP refrigerantsEnergy Conversion and Management, 2021
- Performance evaluation of novel double internal auto-cascade two-stage compression system using refrigerant mixturesApplied Thermal Engineering, 2020
- Design and control of a cryogenic multi-stage compression refrigeration processChemical Engineering Research and Design, 2017
- Experimental investigation of the performance of a single-stage auto-cascade refrigeratorHeat and Mass Transfer, 2015
- Mixed refrigerant composition shift due to throttle valves opening in auto cascade refrigeration systemChinese Journal of Chemical Engineering, 2015
- Exergy and energy analysis of three stage auto refrigerating cascade system using Zeotropic mixture for sustainable developmentEnergy Conversion and Management, 2014
- Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor–liquid separators and environmentally benign binary refrigerantsApplied Energy, 2013