Intra-arterial blood gas monitoring system: More accurate values can be obtained
Authors:
- 1 March 1996
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 12 (2) , 141-147
Abstract
Objective. To compare values measured by a continuous intra-arterial blood gas monitoring system with those measured by conventional blood gas analyzer for the assessment of the clinical performance of a new device for measurement of PaO2, PaCO2, and arterial pH.Methods. Forty-six patients undergoing cardiopulmonary bypass were enrolled in this study. All patients had a continuous intra-arterial sensor (PB 3300) placed into the radial artery through a 20-gauge catheter. A total of 319 arterial blood gas and pH values were obtained for comparison with a conventional blood gas analyzer. The measurements were performed every 12 hrs after the initialin vitro calibration of the sensor for each patient.Results. Measurements were made over a range of 12 to 192 hrs. The overall bias and precision determined by the two methods were 4.5 and 17.1 mmHg for PaO2; 4.5 and 6.2 mmHg for PaCO2; and 0.009 and 0.035 for pH, respectively. For the range of PO2 less than 150 mmHg, the bias and precision improved to 4.2 and 9.5 mmHg. The sensor-derived PCO2 value, PCO2(IABG), increased significantly more than the conventional blood gas analysis value, PCO2(ABG), even within 72 hrs (2.8 and 4.1 mmHg). The relationship between the two measurements can be described as: PCO2(IABG)/PCO2(ABG) = 1 + 0.0026 ·t where t is the time period of use (in hours). By correcting the PCO2(IABG) value using this formula, the overall bias and precision of the values measured by two methods decreases to −0.4 and 3.6 mmHg.Conclusions. The PO2 and pH values derived from an intra-arterial blood gas monitoring system agreed well with the values measured by a conventional blood gas analyzer. However, the PCO2 value must be corrected due to an increase of drift, especially with extended use for more than 72 hours.Keywords
This publication has 20 references indexed in Scilit:
- Multisite Evaluation of a Continuous Intraarterial Blood Gas Monitoring SystemAnesthesiology, 1994
- A multiparameter sensor for continuous intra-arterial blood gas monitoringCritical Care Medicine, 1994
- Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failureCritical Care Medicine, 1994
- CLINICAL EVALUATION OF CONTINUOUS INTRA-ARTERIAL BLOOD GAS MONITOR IN HYPOXIC, HYPERCAPNIC AND HYPOCAPNIC PATIENTSCritical Care Medicine, 1994
- Initial evaluation of a new intra-arterial blood gas system in humansCritical Care Medicine, 1993
- Clinical performance of a blood gas monitorCritical Care Medicine, 1993
- Continuous Measurement of Intraarterial pHa, Paco2, and Pao2, in the Operating RoomAnesthesia & Analgesia, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The performance characteristics of an intra-arterial oxygen electrodeIntensive Care Medicine, 1981
- Continuous In-vivo Blood-gas Determination in ManAnesthesiology, 1980