Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
Authors:
Open Access
- 2 January 2014
- journal article
- research article
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 48 (2) , 196-201
Abstract
Objective: The aim of this study was to compare the biomechanical properties of minimal invasive sliding antirotator compressive hip screw (MIS–A–CHS), and multiple cannulated screws (CS) on a Pauwels type 3 femoral neck fracture model. Methods: A Pauwels type 3 vertical femoral neck fractures was created on 12 third-generation proximal femur models which were divided into two equal groups. The fracture was fixed with three CS in the first group, and MIS–A–CHS in the second group. The axial and rotational stiffness and maximum compression effect were compared between the groups. Results: The axial and rotational stiffness and maximum compression were significantly higher in MIS–A–CHS group (912.5 N, 540 N and 10.2 N/m, respectively) than the CS group (627.5N, 380 N, and 3.9 N/m, respectively). Conclusion: MIS–A–CHS appears to be a more secure fixation method in Pauwels type 3 femoral neck fractures than the CS. Özet Çalışma planı: On iki adet üçüncü nesil proksimal femur kemik modelinde Pauwels tip 3 vertikal femur boyun kırığı oluşturuldu ve modeller iki gruba ayrıldı. Birinci gruba üç paralel KV, ikinci gruba MIS–A–CHS ile tespit uygulandı. İki grubun aksiyel ve torsiyonel yüklenmelere karşı dayanıklılıkları ve maksimal kompresyon güçleri hesaplandı ve birbirleri ile karşılaştırıldı. Çıkarımlar: MIS–A–CHS, Pauwels tip 3 femur boyun kırıklarında KV’e göre aksiyel ve torsiyonel kuvvetlere daha dayanıklı olan ve daha fazla kompresyon sağlayan bir tespit yöntemidir.Keywords
This publication has 8 references indexed in Scilit:
- Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel's type C femoral neck fracturesInjury, 2012
- Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fracturesInjury, 2011
- A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip ScrewJournal of Trauma: Injury, Infection & Critical Care, 2011
- Results of Internal Fixation of Pauwels Type-3 Vertical Femoral Neck FracturesJournal of Bone and Joint Surgery, 2008
- A new technique for lag screw placement in the dynamic hip screw fixation of intertrochanteric fractures: decreasing radiation time dramaticallyInternational Orthopaedics, 2008
- Internal Fixation of Undisplaced Femoral Neck Fractures in the Elderly: A Retrospective Comparison of Fixation MethodsJournal of Trauma: Injury, Infection & Critical Care, 2008
- Shortening after Femoral Neck Fracture FixationClinical Orthopaedics and Related Research, 2007
- THE INCREASING INCIDENCE OF FRACTURES OF THE PROXIMAL FEMUR: AN ORTHOPAEDIC EPIDEMICThe Lancet, 1983