Analytical and numerical study of the serviceability performance of partial composite steel-FRP beams
Authors:
- Hothifa N. RojobHRHothifa N. Rojob
- Khaled M. El-SawyKEKhaled M. El-Sawy
- 1 October 2018
- journal article
- research article
- Published by Emerald Publishing in International Journal of Structural Integrity
- Vol. 9 (5) , 625-645
Abstract
Purpose: The purpose of this paper is to introduce a closed-form analytical solution to evaluate the nominal moment capacity and associated deflections of steel-FRP beam systems. The proposed solution takes into consideration the partial composite behavior resulting from the interfacial contact and slip between the subcomponents of the system. Design/methodology/approach: The partial composite action theory was used to develop an elastic analytical solution for the deflection of simply supported composite steel-FRP beams subjected to a mid-span point load. The solution takes into consideration the partial composite behavior of the system that arises from the interlayer slip at the steel-FRP interface. Findings: The developed analytical model is used to predict the nominal moment capacity of the composite beam and the load value at the onset of yielding in the steel subcomponent of the section. The distribution of shear forces induced in the steel fasteners due to the interfacial slip is also obtained analytically. A comparative study is conducted by comparing the analytical results to their counterparts resulting from finite element modeling of the composite steel-FRP system. The agreement between analytical results and finite element predictions validates the accuracy of the derived analytical solution for partial composite steel-FRP beams. Research limitations/implications: The proposed solution applies only to the FRP strips and 6 mm steel bolts used in the study. Originality/value: Recent studies revealed a promising efficiency of using mechanically fastened hybrid FRP sheets in strengthening steel beams. A major advantage of this technique is the ductile behavior of the steel-FRP system. The current paper introduces a closed-form analytical solution to evaluate the nominal moment capacity and associated deflections of steel-FRP beam systems. Forces developed at the steel-FRP interface due to the relative slip between both components are considered in the proposed analytical solution.Keywords
This publication has 9 references indexed in Scilit:
- Experimental study of the flexural response of steel beams strengthened with anchored hybrid compositesThin-Walled Structures, 2016
- Mechanically-fastened hybrid composites for flexural strengthening of steel beamsThin-Walled Structures, 2014
- Interfacial behavior of mechanically anchored FRP laminates for strengthening steel beamsJournal of Constructional Steel Research, 2013
- Exact static analysis of partially composite beams and beam-columnsInternational Journal of Mechanical Sciences, 2007
- FE modelling of bond interaction of FRP bars to concreteStructural Concrete, 2006
- Strengthening of an artificially degraded steel beam utilising a carbon/glass composite systemConstruction and Building Materials, 2006
- Flexural Response of Steel Beams Strengthened with Partial-Length CFRP PlatesJournal of Composites for Construction, 2005
- Progress on understanding debonding problems in reinforced concrete and steel members strengthened using FRP compositesConstruction and Building Materials, 2004
- Composite Beam‐Columns with Interlayer Slip—Exact AnalysisJournal of Structural Engineering, 1993