Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters
Preprint
Abstract
Purpose: Implanted fiducial markers are often used in radiotherapy to facilitate accurate visualization and localization of tumors. Typically, such markers are used to aid daily patient positioning and to verify the target's position during treatment. This work introduces a novel, automated method for identifying fiducial markers in planar x-ray imaging. Methods: In brief, the method consists of automated filtration and reconstruction steps that generate 3D templates of marker positions. The normalized cross-correlation was the used to identify fiducial markers in projection images. To quantify the accuracy of the technique, a phantom study was performed. 75 pre-treatment CBCT scans of 15 pancreatic cancer patients were analyzed to test the automated technique under real life conditions, including several challenging scenarios for tracking fiducial markers. Results: In phantom and patient studies, the method automatically tracked visible marker clusters in 100% of projection images. For scans in which a phantom exhibited 0D, 1D, and 3D motion, the automated technique showed median errors of 39 $\mu$m, 53 $\mu$m, and 93 $\mu$m, respectively. Human precision was worse in comparison. Automated tracking was performed accurately despite the presence of other metallic objects. Additionally, transient differences in the cross-correlation score identified instances where markers disappeared from view. Conclusions: A novel, automated method for producing dynamic templates of fiducial marker clusters has been developed. Production of these templates automatically provides measurements of tumor motion that occurred during the CBCT scan that was used to produce them. Additionally, using these templates with intra-fractional images could potentially allow for more robust real-time target tracking in radiotherapy.Keywords
All Related Versions
- Version 1, 2017-03-11, ArXiv
- Published version: Medical Physics, 44 (2), 364.
This publication has 24 references indexed in Scilit:
- Adaptive motion mapping in pancreatic SBRT patients using Fourier transformsRadiotherapy and Oncology, 2015
- First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target TrackingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- A Method to Estimate Mean Position, Motion Magnitude, Motion Correlation, and Trajectory of a Tumor From Cone-Beam CT Projections for Image-Guided RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV–kV imagingPhysics in Medicine & Biology, 2008
- Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Feasibility of fully automated detection of fiducial markers implanted into the prostate using electronic portal imaging: A comparison of methodsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Flat-panel cone-beam computed tomography for image-guided radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibilityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964