Reliability of induced sputum test is greater than that of throat swab test for detecting SARS-CoV-2 in patients with COVID-19: A multi-center cross-sectional study
Authors:
Open Access
- 19 October 2020
- journal article
- research article
- Published by Taylor & Francis in Virulence
- Vol. 11 (1) , 1394-1401
Abstract
We previously reported that sputum induction was more sensitive than throat swabs for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in two convalescent coronavirus disease 2019 (COVID-19) patients; however, the value and safety of induced sputum testing require further study. We conducted a prospective multi-center cross-sectional study to compare induced sputum to throat swabs for SARS-CoV-2 detection. Confirmed COVID-19 patients from six hospitals in six cities across China who received one or more negative RT-PCR result for SARS-CoV-2 were enrolled, and paired specimens (induced sputum and throat swabs; 56 cases) were assayed. In three paired samples, both the induced sputum and throat swabs were positive for SARS-CoV-2. The positive rate for induced sputum was significantly higher than for throat swabs both overall (28.6% vs 5.4%, respectively; p < 0.01). Patients were divided according to time span from onset of illness to sample collection into the more-than-30-day (n = 26) and less-than-30-day (n = 30) groups. The positive rate for induced sputum was also significantly higher than for throat swabs in the less-than-30-day group (53.3% vs 10.0%, respectively; p < 0.001). For the more-than-30-day group, all paired samples were negative for SARS-CoV-2. Blood oxygen saturation, respiratory rate, and heart rate remained stable during sputum induction and no staff were infected. Because induced sputum is more reliable and has a lower false-negative rate than throat swabs, we believe induced sputum is more useful for the confirmation of COVID-19 and is safer as a criterion for release from quarantine.Keywords
Funding Information
- Clinical Research Project of Affiliated Hospital of Guangdong Medical University
- Guangdong Basic and Applied Basic Research Foundation (2020B1515020004, 2018A0303130269)
This publication has 20 references indexed in Scilit:
- False Negative Tests for SARS-CoV-2 Infection — Challenges and ImplicationsNew England Journal of Medicine, 2020
- SARS-CoV-2 Receptor ACE2 Is an Interferon-Stimulated Gene in Human Airway Epithelial Cells and Is Detected in Specific Cell Subsets across TissuesCell, 2020
- A Review of Salivary Diagnostics and Its Potential Implication in Detection of Covid-19Cureus, 2020
- Effect of Throat Washings on Detection of 2019 Novel CoronavirusClinical Infectious Diseases, 2020
- Polymerase Chain Reaction Assays Reverted to Positive in 25 Discharged Patients With COVID-19Clinical Infectious Diseases, 2020
- Potential preanalytical and analytical vulnerabilities in the laboratory diagnosis of coronavirus disease 2019 (COVID-19)Clinical Chemistry and Laboratory Medicine (CCLM), 2020
- SARS-CoV-2 RNA more readily detected in induced sputum than in throat swabs of convalescent COVID-19 patientsThe Lancet Infectious Diseases, 2020
- Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCREurosurveillance, 2020
- Find the right sample: A study on the versatility of saliva and urine samples for the diagnosis of emerging virusesBMC Infectious Diseases, 2018
- HDAC2 Suppresses IL17A-Mediated Airway Remodeling in Human and Experimental Modeling of COPDChest, 2018