A novel radiofrequency device for the treatment of rhytides and lax skin: A pilot study
Authors:
- 1 January 2009
- journal article
- clinical trial
- Published by Taylor & Francis in Journal of Cosmetic and Laser Therapy
- Vol. 11 (1) , 25-28
Abstract
Background: Radiofrequency devices generate electromagnetic energy to induce dermal heating to a critical temperature of about 65°C, causing collagen to shrink and contract, and this provides a non‐ablative means to improve rhytides and lax skin. Objective: To evaluate the efficacy and safety of a novel radiofrequency device (Photo Bio Care, Thailand) operating at a frequency of 1.75 MHz for the treatment of rhytides and lax skin in Asian patients. Methods: Six female patients (age range, 30–60 years; mean age 48 years) with class I and II facial rhytides and Fitzpatrick skin types III and IV were treated six times at intervals of 2–3 weeks. The forehead, periorbital area, cheeks and nasolabial folds were treated using the following parameters: monopolar mode, pulse duration of 5 s, frequency of 18 Hz, and power of 100 W. No preoperative anesthesia or postoperative treatment were used. The handpiece was applied to the skin in a continuous sweeping motion until the baseline skin temperature was elevated to 40°C, as monitored with a laser thermometer, and this was maintained for 3 minutes. Clinical photographs were taken before, after the sixth treatment and 2 months after the last treatment. Analysis was undertaken through photographic evaluation by non‐treating physicians. Results: At 2 months after the last treatment, mild to moderate (25–50%) clinical improvement was noted in all patients compared to baseline, and all patients were somewhat satisfied with the treatment. The procedure was well tolerated with no unexpected side effects. Discomfort was rated as mild and post‐treatment erythema resolved within 1–2 hours. Conclusion: Treatment with the radiofrequency device can result in mild to moderate clinical improvement of age‐related rhytides and lax skin. The system is safe and inexpensive with no consumables required.Keywords
This publication has 12 references indexed in Scilit:
- Facial skin tightening with an 1100–1800 nm infrared deviceJournal of Cosmetic and Laser Therapy, 2008
- Photoageing: mechanism, prevention and therapyBritish Journal of Dermatology, 2007
- Treatment of skin laxity of the lower face and neck in older individuals with a broad‐spectrum infrared light deviceJournal of Cosmetic and Laser Therapy, 2007
- Monopolar radiofrequency tissue tightening—how we do it in our practiceLasers in Surgery and Medicine, 2006
- Non‐ablative skin tightening with radiofrequency in Asian skinLasers in Surgery and Medicine, 2005
- Radiofrequency Treatment for Middle and Lower Face LaxityArchives of Facial Plastic Surgery, 2004
- Selective electro‐thermolysis in aesthetic medicine: A reviewLasers in Surgery and Medicine, 2004
- Multicenter study of noninvasive radiofrequency for periorbital tissue tighteningLasers in Surgery and Medicine, 2003
- The use of nonablative radiofrequency technology to tighten the lower face and neckSeminars in Cutaneous Medicine and Surgery, 2003
- Collagen tightening induced by carbon dioxide laser versus erbium:YAG laserLasers in Surgery and Medicine, 2000