Comparison of Form in Potential Functions While Maintaining Upright Postures during Exposure to Stereoscopic Video Clips
Authors:
- Hiroki TakadaHTHiroki Takada
- Yasuyuki MatsuuraYMYasuyuki Matsuura
- 1 October 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1062922X,p. 2140-2145
Abstract
Visually induced motion sickness (VIMS) is a well-known phenomenon in viewing video, playing video games and others. The VIMS is caused by sensory conflict, the disagreement between convergence and visual accommodation while viewing 3-dimensional (3D) video clips. The VIMS can be measured by psychological and physiological methods. We propose a mathematical methodology to measure the effect of 3D video clips on the equilibrium function. In this study, body sway in rest is compared with that during exposure to 3D video clips on a liquid crystal display and on a head mounted display. In addition, the Simulator Sickness Questioner (SSQ) was completed immediately afterward. Based on the statistical analysis of the SSQ sub-scores and each index for stabilograms, we succeeded in evaluating the quantity of the VIMS during exposure to the stereoscopic video clips. Moreover, we discuss the metamorphism in the potential functions to control the postures including the Romberg posture and a wide stance with the middle line of heels 20 cm apart while viewing 3Dvideo clips.Keywords
This publication has 11 references indexed in Scilit:
- Combining volumetric edge display and multiview display for expression of natural 3D images2006
- Physical Meaning on Geometrical Index for StabilometryEquilibrium Research, 2003
- Postural Instability and Motion Sickness in a Fixed-Base Flight SimulatorHuman Factors: The Journal of the Human Factors and Ergonomics Society, 2000
- Stochastic processes in postural center-of-pressure profilesExperimental Brain Research, 1997
- Visual accommodation and subject performance during a stereographic object task using liquid crystal shuttersErgonomics, 1996
- Stabilometry. Significance of Locus Length per Unit Area (L/A) in Patients with Equilibrium Disturbances.Equilibrium Research, 1996
- Stabilometry. Significance of Locus Length Per Unit Area (L/A).Equilibrium Research, 1995
- Open-loop and closed-loop control of posture: A random-walk analysis of center-of-pressure trajectoriesExperimental Brain Research, 1993
- Simulator Sickness Questionnaire: An Enhanced Method for Quantifying Simulator SicknessThe International Journal of Aviation Psychology, 1993
- An ecological Theory of Motion Sickness and Postural InstabilityEcological Psychology, 1991