Optimizing pretransfusion antibody detection and identification:a parallel, blinded comparison of tube PEG,solid‐phase, and automated methods
Authors:
- 1 May 2001
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 41 (5) , 621-626
Abstract
BACKGROUND: The ideal pretransfusion testing strategy identifies maximal significant antibodies at minimal cost. Objectives of this study were to compare the characteristics of three testing methods and determine their optimal incorporation into the following generic testing sequence: 1) screen, for antibodies 2) if results are positive, use primary identification method, 3) if results are inconclusive, use secondary identification method.STUDY DESIGN AND METHODS: A total of 2000 consecutive, unselected, coded specimens were tested with three screening methods—PEG IAT, manual and automated solid phase red cell adherence assay (SPRCA). Of 202 positive results, 187 were of sufficient volume and were tested with both PEG and manual SPRCA identification panels, yielding 82 with significant antibodies, plus one that was negative by both methods found on retrospective review of nonstudy results. Calculations were made on the 1985 volume‐sufficient specimens, simulating the possible testing permutations.RESULTS: Manual SPRCA was the most sensitive antibody screen (67/83 = 81%) and the least specific (1840/1902 = 97%); automated SPRCA was the least sensitive (54/83 = 65%) and most specific (1883/1902 = 99%); and PEG was intermediate in both sensitivity (64/83 = 77%) and specificity (1860/1902 = 98%). Of the identification panels, manual SPRCA identified more antibodies than PEG (67 versus 66) but had more inconclusive results (41 versus 20). Of overall strategies, manual SPRCA screening with either sequence of identification methods identified the most antibodies (66). The combination of PEG screen, PEG identification, and manual SPRCA identification identified slightly fewer antibodies (63) but had the lowest reagent cost, total (reagent plus labor) cost, and cost per antibody identified. The sequence of automated SPRCA screening with manual SPRCA identification, and PEG identification had the lowest hands‐on time.CONCLUSIONS: The most cost‐effective pretransfusion strategy is PEG screen with PEG identification, plus manual SPRCA identification when PEG identification is inconclusive.Keywords
This publication has 9 references indexed in Scilit:
- A fully automated blood typing system forhospital transfusion servicesTransfusion, 2000
- Prevalence of GB virus type C/hepatitis G virus RNA and anti-E2 among blood donors in Southeastern FranceTransfusion, 1999
- Comparison of the polyethylene glycol antiglobulin test and the use of enzymes in antibody detection and identificationTransfusion, 1996
- Polyethylene glycol versus low‐ionic‐strength solution in pretransfusion testing: a blinded comparison studyTransfusion, 1994
- Evaluation of the polyethylene glycol‐potentiated indirect antiglobulin testTransfusion, 1990
- Evaluation of the Polyethylene Glycol Antiglobulin Test for Detection of Red Blood Cell AntibodiesVox Sanguinis, 1990
- Evaluation of the Polyethylene Glycol Antiglobulin Test for Detection of Red Blood Cell AntibodiesVox Sanguinis, 1990
- Evaluation of the polyethylene glycol‐indirect antiglobulin test for routine compatibility testingTransfusion, 1989
- Polyethylene Glycol: A New Potentiator of Red Blood Cell Antigen–Antibody ReactionsAmerican Journal of Clinical Pathology, 1987