Activation‐Based Catalase Enzyme Electrode and its Usage for Glucose Determination
Authors:
- 1 December 2007
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (18) , 3360-3372
Abstract
In this study, a novel type amperometric biosensor, which is based on the activation of catalase enzyme by glucose, was developed and used for the sensitive determination of glucose. For the preparation of the biosensor catalase enzyme was immobilized in gelatin by using cross‐linking agent glutaraldehyde and fixed on a pretreated teflon membrane of a dissolved oxygen probe. Glucose was used as an activator for the catalase enzyme and determination of glucose is based on the assay of the differences on the catalase activity of the biosensor on the oxygenmeter in the absence and the presence of glucose in the reaction medium. The responses of the activation based catalase biosensor have a linear relation to glucose concentrations and good measurement correlation between 0.5 and 5.0 µM with 2 min response time. In the optimization studies of the biosensor the most suitable catalase amount were found as 1324 U cm−2 and also phosphate buffer (pH: 7.0; 50 mM) and 35°C were obtained as the optimum working conditions. For the characterization studies of the biosensor some parameters such as activator and interference effects of some substances on the biosensor response, reproducibility and operational stability were performed.Keywords
This publication has 20 references indexed in Scilit:
- A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon inkBiosensors and Bioelectronics, 2005
- Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensorSensors and Actuators B: Chemical, 2005
- Biosensor based on platinum chips for glucose determinationAnalytica Chimica Acta, 2005
- Biosensors for real-time in vivo measurementsBiosensors and Bioelectronics, 2005
- A novel glucose sensor system with Au nanoparticles based on microdialysis and coenzymes for continuous glucose monitoringSensors and Actuators A: Physical, 2003
- Market analysis of biosensors for food safetyBiosensors and Bioelectronics, 2003
- Design of a composite amperometric enzyme electrode for the control of the benzoic acid content in foodTalanta, 2002
- (Bio)sensors for measurement of analytes implicated in food safety: a reviewTrAC Trends in Analytical Chemistry, 2002
- Microbial biosensorsBiosensors and Bioelectronics, 2001
- The potential role of biosensors in the food and drink industriesBiosensors and Bioelectronics, 1991