Repeatability of pleural adenosine deaminase measurements in diagnostic evaluation of pleural effusions
- 7 December 2017
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 32 (5) , e22371
Abstract
Background: A follow‐up thoracentesis is proposed in suspected atypical tuberculosis cases. The study aimed to define the variability of pleural ADA values across repeated thoracenteses in different types of pleural effusions (PEs) and to evaluate whether ADA variance, in regard to the cutoff value of 40 U/L, affected final diagnosis.Methods: A total of 131 patients with PEs of various etiologies underwent three repeated thoracenteses. ADA values were subsequently estimated.Results: 82% and 55% of patients had greater than 10% and 20% deviation from the highest ADA value, respectively. From those patients who had a variance of 20%, 36% had only increasing ADA values, while 19% had only decreasing values. Considering the cutoff value of 40 U/L, only in two cases, ADA decreased below this threshold, which concerned a man with tuberculous pleurisy and a woman with lymphoma both in the course of treatment. Furthermore, only in two cases with rising values, ADA finally exceeded the cutoff limit, which concerned a man with rheumatoid pleurisy and a man with tuberculous pleurisy. Surprisingly, malignant PEs (MPEs) showed a higher percentage of increasing values compared to all other exudates that did not, however, exceed the threshold.Conclusion: The determination of pleural ADA levels is a reproducible method for rapid tuberculosis diagnosis. The detected measurement deviations do not appear to affect final diagnosis. In specific situations, repeated ADA measurements may be valuable in directing further diagnostic evaluation. More investigation is needed to elucidate the possible prognostic significance of the increasing trend in ADA values in MPEs.Keywords
This publication has 30 references indexed in Scilit:
- Factors affecting pleural fluid adenosine deaminase level and the implication on the diagnosis of tuberculous pleural effusion: a retrospective cohort studyBMC Infectious Diseases, 2013
- When pleural potassium exceeds 5.0 mEq/L, high pleural adenosine deaminase levels do not necessarily indicate tuberculous pleuritisRespirology, 2011
- Diagnostic performance of adenosine deaminase activity in pleural fluid: A single-center experience with over 2100 consecutive patientsEuropean Journal of Internal Medicine, 2010
- Update on tuberculous pleural effusionRespirology, 2010
- Mycobacterium tuberculosis and polymorphonuclear pleural effusion: Incidence and clinical pointersRespiratory Medicine, 2009
- Tuberculous Effusion: ADA Activity Correlates with CD4+ Cell Numbers in the Fluid and the PleuraRespiration, 2005
- Adenosine Deaminase Levels in Nontuberculous Lymphocytic Pleural EffusionsChest, 2001
- Adenosine deaminase isozymes in tuberculous pleural effusionJournal of Laboratory and Clinical Medicine, 1996
- Value of adenosine deaminase in the diagnosis of tuberculous pleural effusions in young patients in a region of high prevalence of tuberculosis.Thorax, 1995
- Pleural Fluid Adenosine Deaminase and Lymphocyte Proportion: Clinical Usefulness In the Diagnosis of TuberculosisCytopathology, 1994