Diagnostic accuracy of MALDI-TOF mass spectrometry for non-small cell lung cancer: a meta-analysis
Authors:
- 22 November 2017
- journal article
- research article
- Published by Taylor & Francis in Biomarkers
- Vol. 23 (3) , 245-252
Abstract
Objective: To assess the overall accuracy of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in identifying non-small cell lung cancer (NSCLC). Methods: A comprehensive search of PubMed, EMBASE and CNKI databases as well as the reference lists from relevant articles was performed prior to July 2017. Two authors independently screened articles based on inclusion and exclusion criteria and assessed the quality of each study using the Quality Assessment of Diagnostic Accuracy Studies 2 (QADAS-2) tool. Meta-disc 1.4 and Stata12.0 software programs were used for the statistical analysis. Results: Eleven eligible articles comprising 16 studies and representing 935 subjects were included in this meta-analysis. The pooled sensitivity and specificity were 0.84 (95% CI: 0.80–0.87) and 0.77 (95% CI: 0.74–0.80), respectively. The overall diagnostic performance as measured by the area under the curve (AUC) for the summary receiver-operating characteristic (SROC) curve was 0.9380. Conclusions: MALDI-TOF MS has a high diagnostic accuracy for NSCLC.Keywords
This publication has 35 references indexed in Scilit:
- Comparison of plasma from healthy nonsmokers, smokers, and lung cancer patients: Pattern-based differentiation profiling of low molecular weight proteins and peptides by magnetic bead technology with MALDI-TOF MSBiomarkers, 2012
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic ScreeningThe New England journal of medicine, 2011
- Discrimination Analysis of Mass Spectrometry Proteomics for Lung Adenocarcinoma DetectionLaboratory Medicine, 2011
- Detection of Lung Cancer Using Plasma Protein Profiling by Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryEuropean Journal of Mass Spectrometry, 2010
- Detection of Tumor Epidermal Growth Factor Receptor Pathway Dependence by Serum Mass Spectrometry in Cancer PatientsCancer Epidemiology, Biomarkers & Prevention, 2010
- Diagnostic Accuracy of MALDI Mass Spectrometric Analysis of Unfractionated Serum in Lung CancerJournal of Thoracic Oncology, 2007
- Measuring inconsistency in meta-analysesBMJ, 2003
- Mass Spectrometry-based Diagnostics: The Upcoming Revolution in Disease DetectionClinical Chemistry, 2003
- Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1988