Intertest Variability of mfVEP Amplitude: Reducing its Effect on the Interpretation of Sequential Tests
- 1 November 2005
- journal article
- research article
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 111 (3) , 159-167
Abstract
Purpose: The multi-focal visual evoked potential (mfVEP) has been recently introduced as an alternative to subjective perimetry in detecting visual field defects. This study examines the source of variability in the mfVEP amplitude, and determines the relationship of this variability to the strength of the signal itself across the visual field. It also investigates possible means to reduce the effects of this variability on between-test interpretation to allow for easier detection of progression. Methods: 85 normal subjects participated in the study. The mfVEP was recorded using AccumapTM (ObjectiVision Pty Ltd, Sydney, Australia). Each subject was tested twice with an interval between visits of 3–4 weeks. Comparison between tests was performed using coefficient of variability (CV). Variability was also analysed using scaling and clustering procedures. Results: In the majority of the retinal areas CV fell within 15–20%. Variability increased with eccentricity, but there was no age dependency. There was a significant reduction of variability (by 15.8 ± 6%, Student’s t-test pt-test pConclusion: Between test comparisons of raw mfVEP traces is limited by a variability of at least 15%. While this variability required the amplitude of the individual VEP signal to change by 30–40% in order to detect progression, scaling and clustering procedures were able to reduce the required change to 20–25%, thus making an interpretation of consecutive test results more clinically viable.Keywords
This publication has 16 references indexed in Scilit:
- Clinical Application of Objective Perimetry Using Multifocal Visual Evoked Potentials in Glaucoma PracticeArchives of Ophthalmology (1950), 2005
- Objective perimetry using the multifocal visual evoked potential in central visual pathway lesionsBritish Journal of Ophthalmology, 2005
- Test–Retest Variability of Multifocal Visual Evoked Potential and SITA Standard Perimetry in GlaucomaInvestigative Ophthalmology & Visual Science, 2004
- Determining abnormal latencies of multifocal visual evoked potentials: a monocular analysisDocumenta Ophthalmologica, 2004
- A principal component analysis of multifocal pattern reversal VEPJournal of Vision, 2004
- Repeat Reliability of the Multifocal Visual Evoked Potential in Normal and Glaucomatous EyesJournal of Glaucoma, 2003
- Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucomaProgress in Retinal and Eye Research, 2003
- Multifocal objective perimetry in the detection of glaucomatous field lossAmerican Journal of Ophthalmology, 2002
- Objective perimetry in glaucoma11Proprietary interest: patent application submitted.Ophthalmology, 2000
- Objective Perimetry in GlaucomaSurvey of Ophthalmology, 1999