Detailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance Study
Open Access
- 21 November 2012
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (11) , e49963
Abstract
The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF) simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR) limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study.Keywords
This publication has 41 references indexed in Scilit:
- The aging Canadian population and hospitalizations for acute myocardial infarction: projection to 2020BMC Cardiovascular Disorders, 2012
- Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarctionJournal of Cardiovascular Magnetic Resonance, 2012
- Improved Detection of Myocardial Involvement in Acute Inflammatory Cardiomyopathies Using T2 MappingCirculation: Cardiovascular Imaging, 2012
- From Molecules to Myofibers: Multiscale Imaging of the MyocardiumJournal of Cardiovascular Translational Research, 2011
- On T2* Magnetic Resonance and Cardiac IronCirculation, 2011
- Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promisesEuropean Radiology, 2010
- Molecular and Microstructural Imaging of the MyocardiumCurrent Cardiovascular Imaging Reports, 2010
- Experimental and numerical assessment of MRI‐induced temperature change and SAR distributions in phantoms and in vivoMagnetic Resonance in Medicine, 2009
- MR thermometryJournal of Magnetic Resonance Imaging, 2008