Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
Authors:
- Huajian华健JI计HUHuajian华健JI计
- Hongming洪明ZHANG张HOHongming洪明ZHANG张
- Bo波LYU吕BOBo波LYU吕
- Liang梁HE何LILiang梁HE何
- Zichao子超LIN林ZIZichao子超LIN林
- Xianghui相辉YIN尹XIXianghui相辉YIN尹
- Yongcai永才SHEN沈YOYongcai永才SHEN沈
- Shuyu舒宇DAI戴SHShuyu舒宇DAI戴
- Hongming ZhangHZHongming Zhang
- Bo LyuBLBo Lyu
Open Access
- 22 May 2024
- journal article
- research article
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 26 (8) , 085105
Abstract
A vacuum ultraviolet (VUV) spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak (EAST). In this study, wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp. The grating angle and charge-coupled device (CCD) position are carefully calibrated for different wavelength positions. The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data, and is required to identify more impurity spectral lines for impurity transport research. Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution. It is found that the impurity emissions in the edge region are still dominated by low-Z impurities, such as carbon, oxygen, and nitrogen, albeit with the application of full-tungsten divertors on the EAST tokamak.Keywords
Funding Information
- University Synergy Innovation Program of Anhui Province (GXXT2021-029)
- Comprehensive Research Facility for Fusion Technology Program of China (2018-000052-73-01-001228)
- National Natural Science Foundation of China (12175278)
- National Natural Science Foundation of China (U23A2077)
- National Natural Science Foundation of China - State Grid Corporation Joint Fund for Smart Grid (12205072)
- National Magnetic Confinement Fusion Science Program of China (2018YFE0303103)
- National Magnetic Confinement Fusion Science Program of China (2019YFE0304002)
This publication has 15 references indexed in Scilit:
- Line identification of boron and nitrogen emissions in extreme- and vacuum-ultraviolet wavelength ranges in the impurity powder dropping experiments of the Large Helical Device and its application to spectroscopic diagnosticsPlasma Science and Technology, 2021
- Development and preliminary test of a space-resolved vacuum-ultraviolet spectroscopy in EASTReview of Scientific Instruments, 2021
- EMC3-EIRENE modelling of tungsten behavior under resonant magnetic perturbations on EAST: Effects of tungsten sputtering and impurity screeningPlasma Physics and Controlled Fusion, 2020
- Development of vacuum ultraviolet spectroscopy for measuring edge impurity emission in the EAST tokamakPlasma Science and Technology, 2020
- Design of the ITER VUV edge imaging spectrometer and R&D for the rotary motional vacuum feed-throughFusion Engineering and Design, 2016
- High Resolution VUV Spectrometer at the INDUS-1 Synchrotron SourceAIP Conference Proceedings, 2007
- Atomic Data for Resonance Absorption Lines. III. Wavelengths Longward of the Lyman Limit for the Elements Hydrogen to GalliumThe Astrophysical Journal Supplement Series, 2003
- Space-resolved VUV spectroscopy using the 3 m normal incidence spectrometer with back-illuminated CCD detector in the LHDReview of Scientific Instruments, 2003
- Measurement and analysis of radiated power components in the JET MkI divertor using VUV spectroscopyJournal of Nuclear Materials, 1997
- A spatially scanning vacuum ultraviolet and visible range spectrometer for spectroscopy of tokamak plasmas in ASDEX-UpgradeReview of Scientific Instruments, 1995