Abstract
Plasmid calibrators are increasingly applied for polymerase chain reaction (PCR) analysis of genetically modified organisms (GMOs). To evaluate the commutability between plasmid DNA (pDNA) and genomic DNA (gDNA) as calibrators, a plasmid molecule, pBSTopas, was constructed, harboring a Topas 19/2 event-specific sequence and a partial sequence of the rapeseed reference gene CruA. Assays of the pDNA showed similar limits of detection (five copies for Topas 19/2 and CruA) and quantification (40 copies for Topas 19/2 and 20 for CruA) as those for the gDNA. Comparisons of plasmid and genomic standard curves indicated that the slopes, intercepts, and PCR efficiency for pBSTopas were significantly different from CRM Topas 19/2 gDNA for quantitative analysis of GMOs. Three correction methods were used to calibrate the quantitative analysis of control samples using pDNA as calibrators: model a, or coefficient value a (Cva); model b, or coefficient value b (Cvb); and the novel model c or coefficient formula (Cf). Cva and Cvb gave similar estimated values for the control samples, and the quantitative bias of the low concentration sample exceeded the acceptable range within ±25 % in two of the four repeats. Using Cfs to normalize the Ct values of test samples, the estimated values were very close to the reference values (bias −13.27 to 13.05 %). In the validation of control samples, model c was more appropriate than Cva or Cvb. The application of Cf allowed pBSTopas to substitute for Topas 19/2 gDNA as a calibrator to accurately quantify the GMO. Graphical AbstractKeywords
This publication has 21 references indexed in Scilit:
- The GMOseek matrix: a decision support tool for optimizing the detection of genetically modified plantsBMC Bioinformatics, 2013
- Detecting un-authorized genetically modified organisms (GMOs) and derived materialsBiotechnology Advances, 2012
- Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessmentAnalytical and Bioanalytical Chemistry, 2009
- Testing for genetically modified organisms (GMOs): Past, present and future perspectivesBiotechnology Advances, 2009
- A procedural approach for the identification of sources of uncertainty associated with GM quantification and real-time quantitative PCR measurementsEuropean Food Research and Technology, 2006
- Role of the “National Reference Centre for Genetically Modified Organisms (GMO) Detection” in the Official Control of Food and FeedVeterinary Research Communications, 2005
- Event-Specific Plasmid Standards and Real-Time PCR Methods for Transgenic Bt11, Bt176, and GA21 Maize and Transgenic GT73 CanolaJournal of Agricultural and Food Chemistry, 2005
- Method validation and reference materialsAccreditation and Quality Assurance, 2004
- Cloned plasmid DNA fragments as calibrators for controlling GMOs: different real-time duplex quantitative PCR methodsAnalytical and Bioanalytical Chemistry, 2003
- A simple procedure for quantification of genetically modified organisms using hybrid amplicon standardsEuropean Food Research and Technology, 2003