Abstract
Tunnel fires often cause huge damage to the lining structure. In order to avoid cracking and spalling of the lining in the case of large-scale tunnel fires and thus ensure the safety of the tunnel, a new tunnel-fire-resistance approach was proposed based on the SiO2 aerogel material. Numerical simulation models of a tunnel were established and the internal temperature distribution of the lining was studied to verify the feasibility of this new approach. The thermal insulation effect between the SiO2 -aerogel-coated lining and the conventional lining under simulating fire was comparatively analyzed. After 1 h of simulating fire, the temperature of the 50-mm-thick concrete on the surface layer of the conventional lining exceeded 600°C. This temperature was enough to cause serious cracking, spalling, and even bursting of the tunnel lining. For the SiO2 -aerogel-coated lining, the internal temperature of the lining was kept below 200°C, and most of the area was even below 100°C. The results indicated that the fire-resistance performance of the tunnel lining can be significantly enhanced by using the SiO2 aerogel coating. In the future, it will have excellent application potential in the field of tunnel-fire protection.

This publication has 28 references indexed in Scilit: