Prevalence of bacterial contamination in 50% dextrose vials in varying storage conditions after multiple punctures
- 4 July 2018
- journal article
- research article
- Published by Wiley in Journal of Small Animal Practice
- Vol. 59 (12) , 758-762
Abstract
Objective: To determine the risk of bacterial growth in single use 50% dextrose vials punctured multiple times and stored in various hospital environments.Materials and Methods: Three groups of three 50% dextrose vials were stored in our hospital intensive care unit at either ambient light or in a darkened drawer at room temperature or refrigerated at 4°C. One vial in each group was punctured either once, once weekly or once daily for 28 days and samples taken for bacterial culture every 7 days until completion of the project. A fourth group of three vials were inoculated with several species of bacteria and stored in our microbiology laboratory under the environmental conditions described above with cultures performed every 7 days for 28 days. In addition, the water activity of 50% dextrose was determined using commercial laboratory equipment.Results: Scant growth of Escherichia coli and Enterobacter agglomerans was detected in cultures performed on day 7, but not subsequent time points, from the inoculated refrigerated vials. The vial punctured once daily for 28 days and stored under refrigerated conditions showed growth of Bacillus subtilis on day 28. All remaining bottles had no bacterial growth at any time point or environmental condition. The water activity of 50% dextrose was 093 at 24°C and 092 at 4°C.Clinical Significance: Bacterial growth in 50% dextrose vials was uncommon even when inoculated with pathogens. Bacterial growth only occurred in refrigerated storage conditions. The water activity of 50% dextrose is not low enough to inhibit all bacterial and fungal growth.Keywords
This publication has 11 references indexed in Scilit:
- Water2012
- Fluid Therapy in Endocrine and Metabolic Disorders2012
- Disorders of Sodium and Water2012
- MALDI-TOF mass spectrometry tools for bacterial identification in clinical microbiology laboratoryClinical Biochemistry, 2011
- The prevalence of multidose vial contamination by aerobic bacteria in a major teaching hospital, Shiraz, Iran, 2006American Journal of Infection Control, 2009
- Water Activity: Fundamentals and Relationships2007
- Appendix D: Minimum Water Activity Limits for Growth of Microorganisms2007
- Enterobacter cloacae and Pseudomonas aeruginosa polymicrobial bloodstream infections traced to extrinsic contamination of a dextrose multidose vialThe Journal of Pediatrics, 1998
- Postoperative Infections Traced to Contamination of an Intravenous Anesthetic, PropofolNew England Journal of Medicine, 1995
- Defining unnecessary disinfection procedures for single-dose and multiple-dose vialsAmerican Journal of Critical Care, 1994