Tension band wiring for simple olecranon fractures: evaluation of surgical technique
Authors:
- On Behalf Of The Shoulder Elbow PlatformOPOn Behalf Of The Shoulder Elbow Platform
- Femke M. A. P. ClaessenFCFemke M. A. P. Claessen
- Michel P. J. van Den BekeromMBMichel P. J. van Den Bekerom
- C. Niek van DijkCDC. Niek van Dijk
- J. Carel GoslingsJGJ. Carel Goslings
- Gino M. M. J. KerkhoffsGKGino M. M. J. Kerkhoffs
- Job N. DoornbergJDJob N. Doornberg
Open Access
- 28 February 2017
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 18 (3) , 275-281
Abstract
In some settings, specific techniques for open reduction and internal fixation are preferred based on the eminence of a surgeon or professional organization. An emphasis on technical aspects of surgery that are not proved superior and vary substantially from surgeon to surgeon can be confusing for trainees. This study applied a numerical grading of the technical aspects of tension band wire (TBW) fixation for olecranon fracture; assessed the interobserver agreement of each criterion; and measured the correlation of the technical grading and objective and subjective long-term outcomes. Forty observers were invited to rate the technical aspects of TBW fixation of the olecranon on 26 post-operative radiographs. The interobserver reliability of the rating was measured using the intra-class correlation coefficient. The correlation between the rating and motion, Mayo elbow performance index, and disabilities of the arm, shoulder and hand score was tested with the Spearman’s rank correlation test. None of the figure-of-eight TBW constructs were considered perfect according to the numerical grading: the majority of observers found three deviations per fixation. The interobserver agreement was only fair for the total number of deviations and no correlation between the number of deviations and long-term objective and subjective outcome was found. A rating of the technical aspects of TBW for olecranon fractures was unreliable and did not correlate with subjective and objective outcomes. Emphasis on specific technical aspects of fixation might be confusing for trainees and could distract them from the principles of effective treatment. Level IV diagnostic study.Keywords
This publication has 18 references indexed in Scilit:
- Measurement of Upper Extremity Disability Using the Patient-Reported Outcomes Measurement Information SystemThe Journal of Hand Surgery, 2014
- A134: Validation of Patient Reported Outomes Measurement Information System Modules for use in Childhood‐;onset LupusArthritis & Rheumatology, 2014
- Long-term Outcome of Displaced, Transverse, Noncomminuted Olecranon FracturesClinical Orthopaedics and Related Research, 2014
- Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfectionInternational Orthopaedics, 2013
- Computerized Adaptive Testing of Psychological FactorsJournal of Bone and Joint Surgery, 2013
- Fractures in Brief: Olecranon FracturesClinical Orthopaedics and Related Research, 2012
- Interobserver Reliability of Radial Head Fracture Classification: Two-Dimensional Compared with Three-Dimensional CTJournal of Bone and Joint Surgery, 2011
- Is tension band wiring technique the "gold standard" for the treatment of olecranon fractures? A long term functional outcome studyJournal of Orthopaedic Surgery and Research, 2008
- Olecranon fractures in adults: factors influencing outcomeInjury, 2004
- Fractures of the OlecranonClinical Orthopaedics and Related Research, 2002