Animal experiment on osseointegration of porous titanium root analogue implants with composite CSn-TAK242 coating
Open Access
- 3 October 2025
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1673758
Abstract
Objective: Chitosan nanoparticles loaded with TLR4 inhibitors (TAK242) were coated on porous titanium root analogue implants and placeded into beagles to investigate the role of TLR4 inhibitors in inhibiting inflammatory reactions and promoting osseointegration in vivo.Methods: The control group consisted of porous titanium root analogue implants fabricated via digital medical technology and 3D printing, while the experimental group included porous titanium root analogue implants with CSn and CSn-TAK242 bioactive coatings. Three groups of implants were inserted into the jaws of dogs, with their stability coefficients immediately measured upon implantation. After 3 months, samples were collected, and the bone integration and gingival attachment of the three groups were assessed using X-rays, Micro-CT, and histological section staining.Results: All groups of porous titanium root analogue implants were correctly placed within the alveolar sockets. The stability coefficients of the implants immediately post-implantation in the control group, CSn group, and CSn-TAK242 group were (64.29 ± 4.01), (62.55 ± 1.98), and (64.59 ± 3.28), respectively, with no significant statistical difference (P>0.05). Three months post-surgery, imaging and histological examinations revealed bone integration with the surrounding bone tissue for all implant groups. BIC results showed: control group (68.11 ± 3.63)%, CSn group (71.07 ± 2.83)%, and Csn-TAK242 group (78.6 ± 4.52)%, with the BIC being highest in the CSn-TAK242 group, followed by the CSn group, and lowest in the control group (P<0.05). More importantly, compared with the control group, the BV/TV of the CSn-TAK242 group was significantly higher. In addition, the Tb.Th of the CSn-TAK242 group was significantly higher than that of the control group and CSn group (P<0.05). The smooth structures at the upper ends of the implants had tight gingival tissue attachment.Conclusion: Porous titanium root analogue implants consistent with the target root morphology were successfully fabricated using digital medical technology and 3D printing. The composite CSn-TAK242 coating further enhanced the osseointegration effects of these implants.Keywords
This publication has 36 references indexed in Scilit:
- Trueness and precision of milled and 3D printed root-analogue implants: A comparative in vitro studyJournal of Dentistry, 2023
- Preparation and characterization of thermosensitive hydrogel system for dual sustained-release of chlorhexidine and bovine serum albuminMaterials Letters, 2021
- Studies on the Performance of Molar Porous Root-Analogue Implant by Finite Element Model Simulation and Verification of a Case ReportJournal of Oral and Maxillofacial Surgery, 2020
- The clinical significance of implant stability quotient (ISQ) measurements: A literature reviewJournal of Oral Biology and Craniofacial Research, 2020
- The effect of doxycycline-containing chitosan/carboxymethyl chitosan nanoparticles on NLRP3 inflammasome in periodontal diseaseCarbohydrate Polymers, 2020
- Effects of immediately static loading on osteointegration and osteogenesis around 3D-printed porous implant: A histological and biomechanical studyMaterials Science and Engineering: C, 2020
- Improvements on biological and antimicrobial properties of titanium modified by AgNPs-loaded chitosan-heparin polyelectrolyte multilayersJournal of Materials Science: Materials in Medicine, 2019
- Fatigue and biological properties of Ti-6Al-4V ELI cellular structures with variously arranged cubic cells made by selective laser meltingJournal of the Mechanical Behavior of Biomedical Materials, 2018
- Fabrication of graded porous titanium–magnesium composite for load-bearing biomedical applicationsMaterials & Design (1980-2015), 2015
- Peri-implant bone reactions at delayed and immediately loaded implants: an experimental studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2008