FRET Visualization of High Mechanosensation of von Willebrand Factor to Hydrodynamic Force
Open Access
- 14 April 2025
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 248
Abstract
Von Willebrand factor (vWF) is a large glycoprotein in the circulation system, which senses hydrodynamic force at vascular injuries and then recruits platelets in assembling clots. How vWF mechanosenses shear flow for molecular unfolding is an important topic. Here, a Förster resonance energy transfer (FRET) biosensor was developed to monitor vWF conformation change to hydrodynamic force. The vWF-based biosensor is anchored on the cell surface, in which the A2 domain is flanked with a FRET pair. With 293T cells seeded into microfluidic channels, 2.8 dyn/cm2 of shear force (i.e., 28 μN/cm2, or 264.1/s in shear rate) induced a remarkable FRET change (~60%) in 30 min. A gradient micro-shear below 2.8 dyn/cm2 demonstrated FRET responses positively related to flow magnitudes, with 0.14 dyn/cm2 (1.4 μN/cm2) inducing an obvious change (~16%). The FRET increases indicate closer positioning of A2’s two terminals in vWF or the addition of a more parallel orientation of the FRET pair, supported with the high FRET of the A2-only-based biosensor, which probably resulted from flow-induced A2 dissociation from vWF intramolecular binding such as that in A1/A3 domains. Interestingly, gradient flow increases from 2.8 to 28 dyn/cm2 led to decreasing FRET changes, suggesting the second-level unfolding in the A2 domain. The LOCK-vWF biosensor with bridged A2 two terminals or an A2-only biosensor could not sense the shear, indicating a structure-flexible A2 and large vWF molecules that are important in the mechanosensation. In conclusion, the developed vWF-based biosensor demonstrated the high mechanosensation of vWF with two-level unfolding to shear force: the dissociation of the A2 domain from vWF intramolecular binding under a micro-shear, and then the unfolding of A2 in vWF under a higher shear; the FRET response to shear force at a very low scale may support the observed clot formation at microvascular wounds. This study provides new insights into the vWF’s mechanosensitive feature for its physiological functions and implicated disorders.Keywords
All Related Versions
Funding Information
- National Natural Science Foundation of China (12372312, 12272063)
- Projects of the “Jiangsu Specially-Appointed Professor” (12372312, 12272063)
This publication has 61 references indexed in Scilit:
- GPIbα-vWF Rolling under Shear Stress Shows Differences between Type 2B and 2M von Willebrand DiseaseBiophysical Journal, 2011
- The effect of shear stress on protein conformationBiophysical Chemistry, 2010
- Unfolding the A2 Domain of Von Willebrand Factor with the Optical TrapBiophysical Journal, 2010
- Structural specializations of A2, a force-sensing domain in the ultralarge vascular protein von Willebrand factorProceedings of the National Academy of Sciences, 2009
- Determination of hierarchical relationship of Src and Rac at subcellular locations with FRET biosensorsProceedings of the National Academy of Sciences, 2008
- Visualization of Polarized Membrane Type 1 Matrix Metalloproteinase Activity in Live Cells by Fluorescence Resonance Energy Transfer ImagingJournal of Biological Chemistry, 2008
- Purified A2 domain of von Willebrand factor binds to the active conformation of von Willebrand factor and blocks the interaction with platelet glycoprotein IbαJournal of Thrombosis and Haemostasis, 2007
- Characterization of Recessive Severe Type 1 and 3 von Willebrand Disease (VWD), Asymptomatic Heterozygous Carriers Versus Bloodgroup O-Related von Willebrand Factor Deficiency, and Dominant Type 1 VWDClinical and Applied Thrombosis/Hemostasis, 2006
- Prophylaxis and von Willebrand's disease (vWD)Thrombosis Research, 2006
- VON WILLEBRAND'S DISEASEAnnual Review of Medicine, 1997