A Novel Ultrasonic Doppler Fetal Heart Rate Detection System Using Windowed Digital Demodulation
Open Access
- 25 May 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 79326-79342
Abstract
Fetal heart rate (FHR) is an essential indicator of fetal well-being. The ultrasonic Doppler FHR detector is widely used to monitor the fetus's health due to its advantages of non-invasion, high sensitivity, and good directivity. However, the existing commercial Doppler FHR detector primarily uses an analog multiplier for demodulation, which has limited functions and insufficient sensitivity. The analog demodulation is performed only on a single-sideband signal(in-phase or quadrature) (IQ), which is impossible to derive the fetal heart movement's vector velocity. Moreover, repetitive recognition of the mitral valve's positive and negative motion easily causes the measured FHR twice the actual one (FHR doubling). Although the traditional digital demodulation FHR detector can obtain in-phase and quadrature demodulation signals, it needs a high-level field-programmable gate array chip and therefore cannot meet low-power consumption requirements in battery-powered situations. Herein we proposed a novel digital demodulation FHR algorithm using time-domain windowing. Then, we applied the algorithm into a low-power complex programmable logic device to achieve low-cost acquisition of vector velocity and suppress FHR doubling and finally designed a hand-held, noninvasive digital Doppler FHR detection system for continuous perinatal detection. In this work, the comparison curve between the TREND curve generated by the simulator and the measured curve of our FHR detector was obtained. The comparative experiment between the commercial FM-3A FHR detector and our proposed FHR detector was performed, and the relative error and standard error of the obtained FHR data were used to evaluate the two FHR detectors' detection accuracy. The results showed that our FHR detector showed excellent detection accuracy at an accuracy rate of 98%, which was much higher than the average accuracy of the FM-3A FHR detector and indicated our proposed digital FHR detector showed excellent detection performance. It means that the proposed digital windowed FHR demodulation algorithm is practical, the multi-FHR monitoring system is feasible, and our proposed FHR detector has high detection accuracy, effectively suppresses FHR doubling, and meets the requirements of Chinese national standards. It provides an alternative scheme towards the low-cost hand-held digital demodulation FHR detection application.Keywords
Funding Information
- Discipline Construction Capacity Improvement Project of Shenzhen Health and Family Planning Commission (SZXJ2018014)
- National Natural Science Foundation of China (81771841, 91859122, 81471735, 81971637)
This publication has 23 references indexed in Scilit:
- Doppler Ultrasound Technology for Fetal Heart Rate Monitoring: A ReviewIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2019
- An open source autocorrelation-based method for fetal heart rate estimation from one-dimensional Doppler ultrasoundPhysiological Measurement, 2019
- Trends in fetal monitoring through phonocardiography: Challenges and future directionsBiomedical Signal Processing and Control, 2017
- A test and simulation device for Doppler-based fetal heart rate monitoringTurkish Journal of Electrical Engineering and Computer Sciences, 2015
- Fetal magnetocardiography (fMCG): moving forward in the establishment of clinical reference data by advanced biomagnetic instrumentation and analysisJournal of Perinatal Medicine, 2012
- Transabdominal Fetal Heart Rate Detection Using NIR Photopleythysmography: Instrumentation and Clinical ResultsIEEE Transactions on Biomedical Engineering, 2009
- Medical ultrasound imagingProgress in Biophysics and Molecular Biology, 2007
- Continuous fetal heart rate monitoring during late gestation in cattle by means of Doppler ultrasonography: Reference values obtained by computer-assisted analysisTheriogenology, 2006
- A new algorithm for detecting fetal heart rate using ultrasound Doppler signalsUltrasonics, 2004
- Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domainPhysiological Measurement, 2004