Smart wristband with integrated chemical sensors for detecting glucose levels using breath volatile organic compounds
Authors:
- 2 May 2019
- conference paper
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11020, 26
Abstract
This paper presents a microcontroller-based solution to classify blood glucose levels using acetone and ethanol breath volatile organic compounds. Two metal oxide semiconductor-based chemical sensors able to detect acetone and ethanol at parts per million concentrations were used. The sensors were tested in a controlled setup with humidified air spiked with acetone and ethanol, mimicking human breath corresponding to low and high blood glucose groups. A support vector machine algorithm was trained and implemented in a microcontroller. In a real time-time test, the trained algorithm classified low and high blood glucose groups with 97% accuracy. Subsequently, a smart wristband prototype that integrates the two sensors was developed. An Arduino-based wearable microcontroller platform was used for its small formfactor and a low-power operation. The wristband is enclosed in a 3D printed housing and powered by an onboard 3.7 V 500 mAh rechargeable Li-ion battery. A smartphone app communicates with the wristband through Bluetooth, allows data visualization, and saves data in the cloud. The presented work makes a significant contribution towards the development of a wearable device for detecting blood glucose levels from a patient’s breath.Keywords
This publication has 13 references indexed in Scilit:
- Dogs Can Be Successfully Trained to Alert to Hypoglycemia Samples from Patients with Type 1 DiabetesDiabetes Therapy, 2015
- Highly sensitive carbon nanotubes–SnO2 nanocomposite sensor for acetone detection in diabetes mellitus breathSensors and Actuators B: Chemical, 2014
- Diabetic Alert Dogs: A Preliminary Survey of Current UsersDiabetes Care, 2013
- Selective Diagnosis of Diabetes Using Pt-Functionalized WO3 Hemitube Networks As a Sensing Layer of Acetone in Exhaled BreathAnalytical Chemistry, 2012
- The clinical potential of exhaled breath analysis for diabetes mellitusDiabetes Research and Clinical Practice, 2012
- Si:WO3 Sensors for Highly Selective Detection of Acetone for Easy Diagnosis of Diabetes by Breath AnalysisAnalytical Chemistry, 2010
- Finger-Stick Glucose MonitoringDiabetes Care, 2010
- Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clampsJournal of Breath Research, 2009
- Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial ReportDiabetes Technology & Therapeutics, 2005
- Increased breath biomarkers of oxidative stress in diabetes mellitusClinica Chimica Acta, 2004