Disruption and Activation of Blood Platelets in Contact with an Antimicrobial Composite Coating Consisting of a Pyridinium Polymer and AgBr Nanoparticles
Authors:
- 27 August 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 1 (9) , 2049-2054
Abstract
Composite materials made up from a pyridinium polymer matrix and silver bromide nanoparticles embedded therein feature excellent antimicrobial properties. Most probably, the antimicrobial activity is related to the membrane-disrupting effect of both the polymer matrix and Ag+ ions; both may work synergistically. One of the most important applications of antimicrobial materials would be their use as surface coatings for percutaneous (skin-penetrating) catheters, such as central venous catheters (CVCs). These are commonly used in critical care, and serious complications due to bacterial infection occur frequently. This study aimed at examining the possible effects of a highly antimicrobial pyridinium polymer/AgBr composite on the blood coagulation system, i.e., (i) on the coagulation cascade, leading to the formation of thrombin and a fibrin cross-linked network, and (ii) on blood platelets. Evidently, pyridinium/AgBr composites could not qualify as coatings for CVCs if they trigger blood coagulation. Using a highly antimicrobial composite of poly(4-vinylpyridine)-co-poly(4-vinyl-N-hexylpyridinium bromide) (NPVP) and AgBr nanoparticles as a thin adherent surface coating on Tygon elastomer tubes, it was found that contacting blood platelets rapidly acquire a highly activated state, after which they become substantially disrupted. This implies that NPVP/AgBr is by no means blood-compatible. This disqualifies the material for use as a CVC coating. This information, combined with earlier findings on the hemolytic effects (i.e., disruption of contacting red blood cells) of similar materials, implies that this class of antimicrobial materials affects not only bacteria but also mammalian cells. This would render them more useful outside the biomedical field.Keywords
This publication has 20 references indexed in Scilit:
- The relationship between the antimicrobial effect of catheter coatings containing silver nanoparticles and the coagulation of contacting bloodBiomaterials, 2009
- The effect of ex vivo anticoagulants on whole blood platelet aggregationPlatelets, 2009
- Central venous catheter-associated infectionsBest Practice & Research Clinical Anaesthesiology, 2008
- Prevention of central venous catheter related infections with chlorhexidine gluconate impregnated wound dressings: a randomized controlled trialAnnals of Hematology, 2008
- A critical review of thromboembolic complications associated with central venous cathetersCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2008
- Pharmacological Strategies for Inhibition of Thrombin ActivityCurrent Pharmaceutical Design, 2008
- Antibacterial and Hemolytic Activities of Pyridinium Polymers as a Function of the Spatial Relationship between the Positive Charge and the Pendant Alkyl TailAngewandte Chemie International Edition, 2008
- Catheter-Related Thrombosis: A Critical ReviewSupportive Cancer Therapy, 2007
- Silver Bromide Nanoparticle/Polymer Composites: Dual Action Tunable Antimicrobial MaterialsJournal of the American Chemical Society, 2006
- Effect of Hirudin versus Heparin on Hemocompatibility of Blood Contacting Biomaterials: An in Vitro StudyThe International Journal of Artificial Organs, 2005