Mechanical Ventilators as Vehicles of Infection
Authors:
- 1 June 1975
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 19 (3) , 180-186
Abstract
Twenty–five patients from the intensive care unit who had been subjected to tracheostomy and required mechanical respiration were studied. Data are presented concerning the bacteriological controls performed on the tracheal exudates, various parts of the ventilators (Engström Model 200 and Bennett PR–2), and the Wright spirometer.The germs found were mainly pseudomonas, enterobacteriaceae germs and bacteria from the acinetobacter group. There was a high incidence of infections in the tracheostomies of these patients.We found a cause and effect relationship between the contaminating bacteria isolated from the cannula and the bacteria isolated from the tracheal exudates in the case of pseudomonas aeruginosa. However, this was not found to be the case where enterobacteriaceae were concerned. Acinetobacter calcoaceticus were isolated almost exclusively in the ventilators.The study calls attention to the need for rigorous disinfection of ventilators to prevent hospital cross infections.ZUSAMMENFASSUNG: 25 Patienten unserer Intensivbehandlungsstation, die tracheotomiert waren und mechanische Ventilation benötigten, waren die Grundlage dieser Untersuchung. Es werden die Ergebnisse bakteriologischer Kontrollen aus dem Trachealsekret, aus verschiedenen Teilen der Respiratoren (Engström Modell 200 und Bennett PR‐2) und aus dem Wright‐Spirometcr vorgelegt.Die gefundenen Keime waren vorwiegend Pseudomonas, Enterobakterien und Bakterien der Acinetobaktergruppe. Die Tracheostomata dieser Patienten waren zu einem hohen Prozentsatz infiziert.Im Falle der Pseudomonas aeroginosa fanden wir eine Ursache‐Wirkungs‐Relation zwischen den von der Kanüle isolierten kontaminierenden Bakterien und den aus den Trachealexsudaten isolierten Keimen. Im Falle der Enterobakterien fand sich diese Beziehung jedoch nicht. Die oxydierenden gram‐negativen Keime, Acinetobakter, wurden fast ausschließlich aus den Ventilatoren isoliert.Diese Untersuchung unterstreicht die Notwendigkeit rigorosester Sterilisation der Respiratoren zur Vermeidung von Krankenhaus‐Kreuzinfektion.Keywords
This publication has 11 references indexed in Scilit:
- The control of pulmonary sepsis in intensive therapy unitsAnaesthesia, 1973
- Bacterial Colonization Profile With Tracheal Intubation and Mechanical VentilationArchives of Surgery, 1972
- RETROGRADE SPREAD OF ORGANISMS FROM VENTILATOR TO PATIENT VIA THE EXPIRATORY LIMBThe Lancet, 1971
- PSEUDOMONAS IN VENTILATORSThe Lancet, 1970
- The Dienes (Mutual Inhibition) Test In The Investigation Of Proteus InfectionsJournal of Medical Microbiology, 1969
- Pseudomonas aeruginosarespiratory tract infections in patients receiving mechanical ventilationEpidemiology and Infection, 1967
- Typing of Pseudomonas pyocyanea by pyocine productionThe Journal of Pathology and Bacteriology, 1966
- THE USE OF ETHYLENE OXIDE FOR STERILIZATION OF MECHANICAL VENTILATORSBritish Journal of Anaesthesia, 1964
- Respiratory Infection following TracheostomyThorax, 1964
- Tracheostomy in the Management of Respiratory ProblemsNew England Journal of Medicine, 1961