Transcranial Doppler detection of vertebrobasilar vasospasm following subarachnoid hemorrhage.
Authors:
- 1 November 1994
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 25 (11) , 2187-2197
Abstract
Transcranial Doppler sonography is of established value in the detection and monitoring of middle cerebral artery vasospasm. Little information exists on the utility of transcranial Doppler for detection of posterior circulation vasospasm. Cerebral angiography and conventional hand-held transcranial Doppler sonography were compared to determine sensitivity and specificity of transcranial Doppler for detection of vertebral and basilar artery vasospasm. Of 59 consecutive subarachnoid hemorrhage patients with transcranial Doppler angiogram correlations, 42 underwent posterior circulation angiography to evaluate 64 vertebral arteries and 42 basilar arteries during the period of risk for vasospasm and had technically adequate transcranial Doppler examinations within 24 hours of the angiogram. A mean flow velocity of 60 cm/s and above was indicative of both vertebral and basilar artery vasospasm. For the vertebral artery, there were 7 true-positive test results, 42 true-negatives, 6 false-positives (unknown cause in 3, increased collateral flow in 1, adjacent vessel vasospasm in 1, hyperperfusion in 1), and 9 false-negatives (anatomic in 7, operator error in 2). Sensitivity was 44% and specificity was 87.5%. For the basilar artery, there were 10 true-positives, 23 true-negatives, 6 false-positives (unknown cause in 4, hyperemia/hyperperfusion in 1, increased collateral flow in 1), and 3 false-negatives (operator error in 2, tortuous vessel course in 1). Sensitivity was 76.9% and specificity was 79.3%. When the diagnostic criterion was changed to > or = 80 cm/s (vertebral artery) and > or = 95 cm/s (basilar artery), all false-positive results were eliminated (specificity and positive predictive value, 100%). Our data suggest that transcranial Doppler has good specificity for the detection of vertebral artery vasospasm and good sensitivity and specificity for the detection of basilar artery vasospasm. Transcranial Doppler is highly specific (100%) for vertebral and basilar artery vasospasm when flow velocities are > or = 80 and > or = 95 cm/s, respectively.Keywords
This publication has 35 references indexed in Scilit:
- Diagnosis and Monitoring of Subarachnoid Hemorrhage by Transcranial Color-Coded Real-Time SonographyNeurosurgery, 1991
- Transluminal angioplasty for treatment of intracranial arterial vasospasmJournal of Neurosurgery, 1989
- Vasospasm of the Vertebrobasilar System in Cases of Ruptured Intracranial AneurysmNeurosurgery, 1983
- Value of Computed Tomography in the Prediction of Cerebral Vasospasm after Aneurysm RuptureNeurosurgery, 1980
- Relation of Cerebral Vasospasm to Subarachnoid Hemorrhage Visualized by Computerized Tomographic ScanningNeurosurgery, 1980
- Vasospasm assessed by angiography and computerized tomographyJournal of Neurosurgery, 1979
- Regional cerebral blood flow in patients with ruptured intracranial aneurysmsJournal of Neurosurgery, 1979
- An investigation with serial angiography into the evolution of cerebral arterial spasm following aneurysm surgeryJournal of Neurosurgery, 1978
- Effects of subarachnoid hemorrhage on cerebral blood volume, blood flow, and oxygen utilization in humansJournal of Neurosurgery, 1977
- Cerebral blood flow evaluation of prolonged experimental vasospasmJournal of Neurosurgery, 1972