Measuring the Angular Accuracy of a Clinician-Performed Epley Maneuver Used to Treat Benign Paroxysmal Positional Vertigo
Authors:
- 17 November 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (1) , 61-65
Abstract
Introduction: Particle repositioning maneuvers have become the criterion standard for managing benign paroxysmal positional vertigo. The Epley canalolith repositioning maneuver is used to treat posterior canal benign paroxysmal positional vertigo and is successful in up to 90% of cases. However, when performed, there are many clinician variabilities, and angles are approximate. It is not known how accurate each angle needs to be for the target canal to be adequately stimulated. The objective of this study was to measure the angular accuracy of clinician-guided Epley maneuvers using a three-axis accelerometer. Methods: Ten healthy subjects were recruited; participants had no known audio vestibular pathology. Five right-hand–dominant clinicians performed Epley maneuvers on both ears of two different participants. Twenty maneuvers were carried out in total. Angular movements were recorded using a vestibular feedback electronic device, the SHIMMER accelerometer. Data were recorded and analyzed using the EYESWEB Open Platform. Results: Results showed that there was angular error at every stage of the clinician-performed Epley maneuver. The most accurate movement was positioning the head to the left of 45 degrees for a left ear maneuver with an average error of 2.94 degrees. The least accurate was when positioning the patient to face the floor at 135 degrees from supine for a right ear maneuver with an average error of 17.6 degrees. Conclusion: Even when experienced ENT clinicians perform a standard Epley maneuver, there is a wide range of angular inaccuracy at each stage. Face to floor is particularly inaccurate. However, given that a majority of procedures (90%) work on the first attempt, there must be an acceptable but unknown range of angular inaccuracy. Novel technologies could improve the angular accuracy, potentially give better results, and allow a broad range of individuals to perform a more accurate Epley maneuver.Keywords
This publication has 19 references indexed in Scilit:
- The number of procedures required to eliminate positioning nystagmus in benign paroxysmal positional vertigoBrazilian Journal of Otorhinolaryngology, 2015
- Use of BPPV Processes in Emergency Department Dizziness PresentationsOtolaryngology–Head and Neck Surgery, 2012
- Disorders of Balance and Vestibular Function in US AdultsArchives of internal medicine (1960), 2009
- Diagnostic, Pathophysiologic, and Therapeutic Aspects of Benign Paroxysmal Positional VertigoOtolaryngology–Head and Neck Surgery, 2004
- Variables Affecting Treatment in Benign Paroxysmal Positional VertigoThe Laryngoscope, 2000
- Unrecognized benign paroxysmal positional vertigo in elderly patientsOtolaryngology–Head and Neck Surgery, 2000
- Physical Therapy for Benign Paroxysmal Positional VertigoJAMA Otolaryngology–Head & Neck Surgery, 1980
- CupulolithiasisJAMA Otolaryngology–Head & Neck Surgery, 1969
- LXXVIII The Pathology, Symptomatology and Diagnosis of Certain Common Disorders of the Vestibular SystemAnnals of Otology, Rhinology & Laryngology, 1952
- Ueber den „einseitigen Drehschwindel“Journal of Neurology, 1897