Final Clearance Criteria After Mould Remediation
Authors:
- 1 June 2004
- journal article
- research article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 13 (3) , 199-203
Abstract
Final clearance sampling practices for mould abatement projects have not been evaluated. This paper proposes procedures to remedy this. It is suggested that following remediation and after the visual inspection at least five to seven air samples should be collected. These sampling practices can also be used to screen for mould problems as part of a visual inspection and to assist in recognizing a problem dwelling. It is suggested that screening should involve taking at least four samples. To determine if the air concentration of mould is elevated it is necessary to sample inside and outside the building (abatement area). Since these samples have been shown to be non-normal in distribution, transformation is required or non-parametric statistic testing must be performed to determine whether the airborne mould concentration is elevated inside the area of interest (the building).Keywords
This publication has 26 references indexed in Scilit:
- Toxic mold: phantom risk vs scienceAnnals of Allergy, Asthma & Immunology, 2003
- Humid Buildings - The ProblemIndoor and Built Environment, 2003
- Humid Building Problems in MauritiusIndoor and Built Environment, 2003
- Direct Assessment of Microbial Colonisation in Damp Houses by Chemical Marker AnalysisIndoor and Built Environment, 2003
- Bronchoalveolar Lavage Findings from Persons Exposed to Moulds in Water-Damaged HousesIndoor and Built Environment, 2003
- Fungal contamination of elementary schools: a new environmental hazardAnnals of Allergy, Asthma & Immunology, 2003
- Risks Caused by Airborne Microbes in Hospitals - Source Control is ImportantIndoor and Built Environment, 2003
- Effectiveness of Engineering Controls for Airborne Lead Exposure during Renovation/Demolition of a Commercial BuildingIndoor and Built Environment, 2000
- Control of Exposure to Airborne Viable Microorganisms During Remediation of Moldy Buildings; Report of Three Case StudiesAIHA Journal, 1998
- Exposure to Airborne Microbes During the Repair of Moldy BuildingsAIHA Journal, 1996