Signal linearity of an extended range pulse counting detector: Applications to accurate and precise U‐Pb dating of zircon by laser ablation quadrupole ICP‐MS
- 20 November 2010
- journal article
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 11 (11)
Abstract
Element concentration and isotope ratio measurements by single‐collector mass spectrometry often require the detection system to handle ion beams with very large intensity ratios. In order to obtain accurate and reproducible element concentration and isotope ratio data, the detection system must have a linear response with respect to the intensity of the incident ion beam. An extended range scaling pulse counting detector equipped on a Varian 810 quadrupole inductively coupled plasma–mass spectrometer (ICP‐MS) was tested for linearity across count rates of ∼2000 to 110,000,000 cps with different concentrations of natural U solutions. We also tested detector linearity by the laser ablation analysis of 206Pb/238U, 207Pb/235U, and 207Pb/206Pb ratios in well‐characterized 416–1565 Ma zircon standards. Results indicate that there is no correlation between the measured isotope ratio and ion intensity for the solution tests or the tests of natural zircon standards. The results of these tests confirm the suitability of this instrument for isotope ratio measurements that require a substantial dynamic range without having to switch between pulse counting and analog modes on electron multipliers or switching between electron multiplier to Faraday detectors.Keywords
This publication has 11 references indexed in Scilit:
- U‐Pb dating of zircon by LA‐ICP‐MSGeochemistry, Geophysics, Geosystems, 2006
- The application of laser ablation-inductively coupled plasma-mass spectrometry to in situ U–Pb zircon geochronologyChemical Geology, 2004
- Improved 206Pb/238U microprobe geochronology by the monitoring of a trace-element-related matrix effect; SHRIMP, ID–TIMS, ELA–ICP–MS and oxygen isotope documentation for a series of zircon standardsChemical Geology, 2004
- U–Pb ages of detrital zircons from Permian and Jurassic eolian sandstones of the Colorado Plateau, USA: paleogeographic implicationsSedimentary Geology, 2003
- TEMORA 1: a new zircon standard for Phanerozoic U–Pb geochronologyChemical Geology, 2003
- U–Pb dating of detrital zircons for sediment provenance studies—a comparison of laser ablation ICPMS and SIMS techniquesChemical Geology, 2002
- Precise elemental and isotope ratio determination by simultaneous solution nebulization and laser ablation-ICP-MS: application to U–Pb geochronologyChemical Geology, 2000
- Precise U‐Pb ages of Duluth Complex and related mafic intrusions, northeastern Minnesota: Geochronological insights to physical, petrogenetic, paleomagnetic, and tectonomagmatic processes associated with the 1.1 Ga Midcontinent Rift SystemJournal of Geophysical Research, 1993
- Calculation of uncertainties of U-Pb isotope dataEarth and Planetary Science Letters, 1980
- Approximation of terrestrial lead isotope evolution by a two-stage modelEarth and Planetary Science Letters, 1975