A comparison of engineering controls for formaldehyde exposure during grossing activities in health care anatomic pathology laboratories
- 26 April 2016
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 13 (7) , 529-537
Abstract
This article for the first time reports a large set of monitoring results for formaldehyde exposure during grossing activities in health care anatomic pathology laboratories, and compares the effectiveness of different local exhaust ventilation systems on the exposure. To control the confounding effects from grossing work load, sampling duration, and the sizes of specimens grossed, only 15-min short-term personal exposure samples collected during large tissue specimen grossing were used for the comparison of the effectiveness of these local exhaust systems. While we also collected long-term 8-hr time weighted average samples, these are not treated in this analysis. The systems examined were canopy receiving hoods, slot exhausts, and commercially available pre-manufactured backdraft grossing stations, both recirculating and ducted exhaust types. Out of over 2,000 personal short-term air samples, 307 samples from 163 surveys met the data selection criteria. Over a third of the data were less than the analytical laboratory limits of detection. Using the robust maximum likelihood estimation method for multiple limits of detection, the mean and geometric mean of the dataset for each type of local exhaust system were found to be less than the short-term personal exposure regulatory limit of 2 ppm. Nonparametric Wilcoxon rank-sum pairwise tests of five types of engineering controls showed a statistically significant difference among these controls, with the most effective being the manufactured backdraft grossing stations ducted to the outside, and the least effective being canopy exhaust systems and manufactured filtered recirculating grossing stations. Finally, exposure with each of the major engineering control types was rated by the American Industrial Hygiene Association exposure control rating scheme.Keywords
This publication has 17 references indexed in Scilit:
- Personal formaldehyde exposure level in the gross anatomy dissecting room at college of medicine King Saud University RiyadhInternational Journal of Occupational Medicine and Environmental Health, 2011
- Preliminary study: Formaldehyde exposure in laboratories of Sharjah university in UAEIndian Journal of Occupational and Environmental Medicine, 2011
- Anatomy laboratory instruction and occupational exposure to formaldehydeOccupational and Environmental Medicine, 2010
- Local ventilation system successfully reduced formaldehyde exposure during gross anatomy dissection classesAnatomical Science International, 2010
- Prospective study of clinical symptoms and skin test reactions in medical students exposed to formaldehyde gasThe Journal of Dermatology, 2007
- Rating Exposure Control Using Bayesian Decision AnalysisJournal of Occupational and Environmental Hygiene, 2006
- Characterizing Formaldehyde Emission Rates in a Gross Anatomy LaboratoryApplied Occupational and Environmental Hygiene, 2001
- Reducing the levels of formaldehyde exposure in gross anatomy laboratoriesThe Anatomical Record, 1995
- Medical Students' Exposure to Formaldehyde in a Gross Anatomy Dissection LaboratoryJournal of American College Health, 1992
- Formaldehyde Exposure in a Gross Anatomy LaboratoryJournal of Occupational and Environmental Medicine, 1985