Automatic bi-objective parameter tuning for inverse planning of high-dose-rate prostate brachytherapy
- 1 April 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (7) , 075009
Abstract
We present an automatic bi-objective parameter-tuning approach for inverse planning methods for high-dose-rate prostate brachytherapy, which aims to overcome the difficult and time-consuming manual parameter tuning that is currently required to obtain patient-specific high-quality treatment plans. We modelled treatment planning as a bi-objective optimization problem, in which dose-volume-based planning criteria related to target coverage are explicitly separated from organ-sparing criteria. When this model is optimized, a large set of high-quality plans with different trade-offs can be obtained. This set can be visualized as an insightful patient-specific trade-off curve. In our parameter-tuning approach, the parameters of inverse planning methods are automatically tuned, aimed to maximize the two objectives of the bi-objective planning model. By generating trade-off curves for different inverse planning methods, their maximally achievable plan quality can be insightfully compared. Automatic parameter tuning furthermore allows to construct standard parameter sets (class solutions) representing different trade-offs in a principled way, which can be directly used in current clinical practice. In this work, we considered the inverse planning methods IPSA and HIPO. Thirty-nine previously treated prostate cancer patients were included. We compared automatic parameter tuning, random parameter sampling, and the maximally achievable plan quality obtained by directly optimizing the bi-objective planning model with the state-of-the-art optimization software GOMEA. We showed that for each patient, a set of plans with a wide range of trade-offs could be obtained using automatic parameter tuning for both IPSA and HIPO. By tuning HIPO, better trade-offs were obtained than by tuning IPSA. For most patients, automatic tuning of HIPO resulted in plans close to the maximally achievable plan quality obtained by optimizing the bi-objective planning model directly. Automatic parameter tuning was shown to improve plan quality significantly compared to random parameter sampling. Finally, from the automatically-tuned plans, three class solutions were successfully constructed representing different trade-offs.Keywords
Funding Information
- Elekta
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (628.006.003)
This publication has 31 references indexed in Scilit:
- GEC/ESTRO recommendations on high dose rate afterloading brachytherapy for localised prostate cancer: An updateRadiotherapy and Oncology, 2013
- Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR brachytherapyPhysics in Medicine & Biology, 2013
- Impact of using linear optimization models in dose planning for HDR brachytherapyMedical Physics, 2012
- IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indicesMedical Physics, 2011
- An Eight-Year Experience of HDR Brachytherapy Boost for Localized Prostate Cancer: Biopsy and PSA OutcomeInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapyBrachytherapy, 2008
- Minimal displacement of novel self-anchoring catheters suitable for temporary prostate implantsRadiotherapy and Oncology, 2006
- Biological Models in Treatment Planning2006
- Performance assessment of multiobjective optimizers: an analysis and reviewIEEE Transactions on Evolutionary Computation, 2003
- Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithmsPhysics in Medicine & Biology, 2002