Uranyl Ion Extraction into Room Temperature Ionic Liquids: Species Determination by ESI and MALDI-MS
Authors:
- 4 June 2010
- journal article
- research article
- Published by Taylor & Francis in Solvent Extraction and Ion Exchange
- Vol. 28 (4) , 495-509
Abstract
The extraction of uranyl nitrate by TBP in two room temperature ionic liquids (RTILS), viz. 1-alkyl-3 -methyl imidazolium (Cnmim, n = 4 and 8) cation with hexafluorophosphate anion and, for comparison purposes, in dodecane has been studied. The species extracted were determined by slope analysis, UV-VIS spectra and supported for the first time by two known soft ionization mass spectrometric techniques, viz. MALDI-MS and ESI-MS. The results show that the extraction mechanisms differ in the two RTILS, as cation exchange is more likely for a butyl substituted RTIL, C4mimPF6 as noted in literature, whereas the formation of a neutral adduct (i.e., UO2(NO3)22TBP) by a solvation mechanism is operative for octyl analogue, C8mimPF6.Keywords
This publication has 35 references indexed in Scilit:
- Coupled Ion Complexation and Exchange between Aqueous and Ionic Liquid Phases: A Thermodynamic InterpretationSolvent Extraction and Ion Exchange, 2008
- Effect of Anions on the Extraction of Lanthanides (III) by N,N′‐Dimethyl‐N,N′‐Diphenyl‐3‐OxapentanediamideSolvent Extraction and Ion Exchange, 2008
- Interactions of 1-Methylimidazole with UO2(CH3CO2)2 and UO2(NO3)2: Structural, Spectroscopic, and Theoretical Evidence for Imidazole Binding to the Uranyl IonJournal of the American Chemical Society, 2006
- Potentialities of Room Temperature Ionic Liquids for the Nuclear Fuel Cycle: Electrodeposition and Extraction2005
- Detection and Quantification of Lanthanide Complexes in Cell Lysates by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2004
- Room temperature ionic liquid as a novel medium for liquid/liquid extraction of metal ionsAnalytica Chimica Acta, 2003
- Study of thorium hydrolysis species by electrospray-ionization mass spectrometryAnalytica Chimica Acta, 2001
- Traditional Extractants in Nontraditional Solvents: Groups 1 and 2 Extraction by Crown Ethers in Room-Temperature Ionic LiquidsIndustrial & Engineering Chemistry Research, 2000
- Speciation of Uranium by Electrospray Ionization Mass Spectrometry: Comparison with Time-Resolved Laser-Induced FluorescenceApplied Spectroscopy, 2000
- Electrospray mass spectrometric study of ionic derivatives of platinum(II) dithiolates with polyphosphinesInorganic Chemistry, 1992